Faria Instruments SMARTCRAFT MG2000 User Manual

Page 31

Advertising
background image

Page 25

Note: Ensure fuel tank is half full before continuing to the next
step.

Using the “Up” or “Down” buttons display “Calibrate Fuel Half Full”.

Press and hold the “Up” and “Down” buttons for 2 seconds to select
“Calibrate Fuel Half Full”.

Calibrate

Fuel

Half Full

Fill the tank to HALF full before setting this level.

The last line of the display shows the percentage of fuel being sent by
the fuel sender for the half full condition.

Press and hold the “Up” and “Down” buttons for 2 seconds to save
the half full calibration point. Press “Down” to go to the next section.

Fuel

Half Full

Input Fuel%

XX%

The screen returns to the “Calibrate Fuel Half Full” screen,

Calibrate

Fuel

Half Full

Press the “Mode” button to return to the “Edit” mode.

Press the “Up” or “Down” button to select another function or
“Mode” to return to “Normal” mode.

Fuel

Tank

Calibrate

Fuel Tank Calibrate - Full

From the “Edit” mode, using the “Up” or “Down” buttons, select the
“Fuel Tank Calibrate” edit function.

Press and hold the “Up” and “Down” buttons for 2 seconds to select
the “Fuel Tank Calibrate”. Follow the instructions below.

Otherwise,

Press the “Up” or “Down” button to select another function or
“Mode” to return to “Normal” mode.

Fuel

Tank

Calibrate

Note: Ensure the fuel tank is FULL before continuing to the next
step.

Using the “Up” or “Down” buttons display “Calibrate Fuel Full”.

Press and hold the “Up” and “Down” buttons for 2 seconds to select
“Calibrate Fuel Full”.

Calibrate

Fuel

Full