Frymaster Dean SR114E User Manual

Page 5

Advertising
background image

SUPER RUNNER SERIES ELECTRIC FRYERS

CHAPTER 1: INSTALLATION INSTRUCTIONS

1-2

CLEARANCE AND VENTILATION

This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to
combustible construction. No clearance is required when installed adjacent to

non-combustible construction. A

minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer.

INSTALLATION

For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position.
Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not
function efficiently.

A. Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot

on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more
than ¾-inch (19-mm)
.


B. When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the

foot to the required height.

For units equipped with casters: Roll the unit into its final position and lock the front casters.

When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so
that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in
accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or
other reasons, they must be reconnected before the fryer is used.

1.3 Power Requirements

Use copper wire ONLY suitable for at least 194

°F (90°C)

MODEL

VOLTAGE

PHASE

WIRE

SERVICE

MINIMUM WIRE

SIZE

AWG mm

AMPS

(per leg)

14 kW

208

Single

3

4

(5.83)

68

14 kW

208

3

3

8

(4.11)

39

14 kW

240

Single

3

4

(5.19)

59

14 kW

240

3

3

8

(3.26)

34

14 kW

230/400

3

4

6

(4.11)

21

DANGER

The electrical power supply for this appliance MUST be the same as indicated on the rating and serial

number plate located on the inside of the fryer door.

DANGER

This appliance MUST be connected to the voltage and phase specified on the rating and serial

number plate located inside the fryer door.

DANGER

All wiring connections for this appliance MUST be made in accordance with the wiring diagrams

furnished with the equipment. Wiring diagrams are located inside the fryer door.

Advertising