6. MAINTENANCE, TROUBLESHOOTING

6-6

6.8 Diagnostics

1. Press the MENU key to open the menu.
2. Press ▲ to choose MENU, and then press ► to choose SYS.
3. Press

▼ to choose GO TO SYS MENU.

4. Press ◄ to choose YES.
5. Choose TEST and press ► to start the test. The lamps above the XDR switches light

alternately for one second while the test is being conducted. In a few moments the
results of the test appear.

MAIN PROGRAM NO. : 0650111-XX.XX

RAM

: OK

ROM

: OK

VRAM

: OK

NMEA2

: *

NMEA1

: *

PANEL PROGRAM NO. : 0650112-XX.XX

TX FREQUENCY

: 85/215 kHz†

ROLL MS : 10 SC: - - -

PITCH MS : 10 SC: - - -

PULSES

NG

TEST COUNT= : 10

TRAIN

359

0

REMOTE CONTROL

PANEL

0 0 0

0

0

0 0 0

0

EXIT

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0 0

0

0 0

0

0

0

0

0

0

0

* Requires special test connector to test. Nothing displayed when plug is not connected.

† Or 60/153 kHz

XX.XX = Program Version No.

0

Test results

Interpreting the test results display
•

The program numbers of the MAIN and PANEL programs appear at the top of the display.

•

The ROM, RAM, VRAM, NMEA1, NMEA2 and PANEL CPU are checked for proper
operation and the results displayed as OK or NG (No Good). For NG contact a FURUNO
agent or dealer for advice. The NMEA1/NMEA2 test checks the NMEA (monitor unit) /
NMEA (transceiver unit) ports.

•

The TX FREQUENCY of the transducer is measured and displayed.

•

ROLL and PITCH values change with ship’s pitching and rolling (range: -30

° to +30°).