6. MAINTENANCE, TROUBLESHOOTING

6-6

6.8 Diagnostics

1. Press the MENU key to open the menu.
2. Press ▲ to choose MENU, and then press ► to choose SYS.
3. Press

▼ to choose GO TO SYS MENU.

4. Press ◄ to choose YES.
5. Choose TEST and press ► to start the test. The lamps above the XDR switches light

alternately for one second while the test is being conducted. In a few moments the
results of the test appear.

MAIN PROGRAM NO. : 0650111-XX.XX

RAM

: OK

ROM

: OK

VRAM

: OK

NMEA2

: *

NMEA1

: *

PANEL PROGRAM NO. : 0650112-XX.XX

TX FREQUENCY

: 85/215 kHz†

ROLL MS : 10 SC: - - -

PITCH MS : 10 SC: - - -

PULSES

NG

TEST COUNT= : 10

TRAIN

359

0

REMOTE CONTROL

PANEL

0 0 0

0

0

0 0 0

0

EXIT

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0 0

0

0 0

0

0

0

0

0

0

0

* Requires special test connector to test. Nothing displayed when plug is not connected.

† Or 60/153 kHz

XX.XX = Program Version No.

0

Test results

Interpreting the test results display

The program numbers of the MAIN and PANEL programs appear at the top of the display.

The ROM, RAM, VRAM, NMEA1, NMEA2 and PANEL CPU are checked for proper
operation and the results displayed as OK or NG (No Good). For NG contact a FURUNO
agent or dealer for advice. The NMEA1/NMEA2 test checks the NMEA (monitor unit) /
NMEA (transceiver unit) ports.

The TX FREQUENCY of the transducer is measured and displayed.

ROLL and PITCH values change with ship’s pitching and rolling (range: -30

° to +30°).