Advance Planning

ADVANCE PLANNING

Ductwork Planning
• These vent hoods are equipped for 10" round

ductwork. For best performance, use 10" round
ductwork on the 48" wide hoods. 30" and 36" hoods
may be transitioned to 8" round.

• This hood may be vented vertically through upper

cabinets, soffit or ceiling. A duct transition piece is
supplied for vertical exhaust. Use locally supplied
elbows to vent horizontally through the rear wall.

• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible.

For satisfactory performance, duct run should
not exceed 150 ft. equivalent length for any duct
configurations.

• Refer to “Duct Fittings” chart to compute the

maximum permissible length for duct runs to the
outdoors.

• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the

exterior opening. Order the wall or roof cap and any
transition needed in advance.

Wall Framing for Adequate Support
• These vent hoods are heavy. Adequate structural

support must be provided. Hoods must be secured to
vertical studs in the wall.

• It is strongly recommend that the vent hood with

duct cover be on site before final framing and wall
finishing. This will also help to accurately locate the
ductwork and electrical service.

Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available
to fit all models. The duct cover conceals the ductwork
running from the top of the hood to the ceiling or
soffit. Stack one or more duct covers over the top
of the hood to reach your ceiling height.

POWER SUPPLY

IMPORTANT

– (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.

AVERTISSEMENT–

POUR DES

RAISONS DE SÉCURITÉ, CET APPAREIL DOIT
ÊTRE CORRECTEMENT MIS À LA TERRE.

Remove house fuse or open circuit breaker before
beginning installation.

Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.

Electrical supply

These vent hoods must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp circuit
breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above

requirements, call a licensed electrician before
proceeding.

• Route house wiring as close to the installation

location as possible on the back wall or ceiling.

• Connect the wiring to the house wiring in

accordance with local codes.

Grounding instructions

The grounding conductor must be connected
to a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.

WARNING:

The improper connection of

the equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified electrician
or service representative if you are in doubt whether
the appliance is properly grounded.

AVERTISSEMENT

Le mauvais branchement du fil de mise à la terre peut
causer un choc électrique. En cas de doute, consulter
un électricien qualifié ou un technicien pour
déterminer si l’appareil est à la terre.