Series 100 error conditions, Portable dryer troubleshooting, Error codes – GSI Outdoors PNEG-630 User Manual

Page 112

Advertising
background image

Portable Dryer Troubleshooting

111

Series 100 Error Conditions

This indicates that one of the other on

screen errors (vapor, plenum, housing

temp hi-limit, flame out, no airflow, motor

overload or rear discharge) has occured.

Mercoid gas pressure safety.

User supplied safety.

I/O board communication failure

I/O board and master have lost

communication.

No safety circuit voltage.

Illegal flame sense. Error 7 is most likely

caused by stuck open solenoid. Error 7 will

not shut down fan until loss of flame is

detected by control. Error 7 may also be

caused by a bad ballast resistor (ballast

resistor not open between poles). It may als

o

occur if 1 of the 12 volt DC limits is shorted t

o

AC ground, or either temperature senosr is

shorted to AC ground.

Flame probe shorted to AC ground.

Plenum temperature senosr leads are

shorted together OR sensor is shorted.

(See figure 4)

Plenum temperature sensor is open.

One or both leads are off (open circuit)

(See figure 4)

Grain temperature sensor leads are

shorted together OR sensor is shorted.

(See Figure 4)

Grain temperature sensor open. One

or both leads are off (open circuit)

(SEE FIGURE 4)

User switched from continuous flow to

batch while dryer is running.

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

Error Codes