background image

Portable Dryer Troubleshooting

54

Test Procedure for E.M.C.S. Dryers

IF NONE OF THE MEASUREMENTS = 3.4 K,

THEN CHECK EACH INDIVIDUAL SENSOR.

IF MEASUREMENTS DO NOT = 3.4 K

CHECK CONNECTIONS IN WHITE

JUNCTION BOX ON FAR LEFT AND

RIGHT SIDES FACING THE FAN END.

IF OHMS DOES NOT = 3.4 K

CHECK LOWER AND UPPER TERMINAL

STRIP (ON SINGLE MODULES CHECK S1 & S2

)

(ON DOUBLE OR TRIPLE MODULES

CHECK J6-9 TO J6-6 = 3.4 AND

CHECK J6-11 TO J6-8 = 3.4)

MOISTURE

CONTROL

THERMOSTAT

6

5

4

1

2

3

7

8

9

J5-3

S1

S2

3.4 ON 20K

SCALE AT

70 DEGREES

USING OHM METER BEGIN CHECKING

THE SENSORS FOLLOWING FIG. 1

FIG.1

E.M.C.S. PORTABLE DRYERS

Wiring Reference