background image

Portable Dryer Troubleshooting

40

Fenwal Board Troubleshooting

On-Board Diagnostics

The LED will flash on for 0.2 seconds then off for 0.2 seconds to indicate an error condition.
The pause time between error codes will be 2.5 to 3.0 seconds. During power-up, the LED will light
for one second and then turn off to indicate normal operation.

LED Indication Fault Mode
Steady on Internal Control Failure
2 Flashes Flame Fault**
3 Flashes Ignition Lockout Fault

** May indicate either that a flame was detected during

pre- or post-purge, or that there is a flame sensing error.

Micro Amp Meter

Flame

Test

S1

FC+

FC-

+

-

Flame

Test

If a lockout occurs, the board will have to be reset

by shutting off the power to the board.

S1

Measure Flame Current

YES

NO

NO

BURNER

BURNER

BURNER

Wiring Reference