265 volt electrical supply – GE ZONELINE 3200 User Manual

Page 13

Advertising
background image

These models must be installed using one of the
following methods:

A

Electrical subbase kits are available to provide
a flexible enclosure for direct connection.

Branch Circuit

and Chassis

Proper GE

Amperage Rating

Subbase Kit

15

RAK204E15

20

RAK204E20

30

RAK204E30

The instructions provided with the selected
subbase kit must be carefully followed. It is
the responsibility of the installer to ensure
that connection of components is done in
accordance with these instructions and all
electrical codes.

B

For direct connection to branch circuit wiring
inside the provided junction box without using
a subbase kit, the cord is to be cut and the wire
ends stripped and connected as follows.

Steps for preparing cordset for direct connection:

1

Remove the junction box cover by taking out
the front four screws.

2

Remove the junction box by taking out the top
rear screw. Note how the tab at the lower right
corner of the junction box serves to hold the
corner in place. This will help when the box is
being reinstalled. The cord will be coiled up
inside the junction box.

3

Measure 6

down the cord from the strain

relief securing the cord to the chassis and cut
the cord through at this point.

4

Carefully split the cord insulation at the center
for 2

so as to separate into three insulated

wires. Be careful not to cut through the center
green ground wire insulation.

5

Strip 3/4

of the insulation away at the end

of each of the three wires (L1, Neutral and
Ground). The Neutral wire is identified by
molded rib along its entire length. The L1
(Hot) wire insulation is smooth.

265 Volt Electrical Supply

WARNING

Connection of this 265V product to a
branch circuit

MUST

be done by direct

connection to be in compliance with the
National Electric Code. Plugging of this
unit directly into a building mounted
exposed receptacle is not permitted
by code.

13

6

2

3/4

Slot in
junction box

Strain
relief

Junction
box cover

Junction box

Strain
relief

Ground
wire

L1 wire
(smooth)

Neutral wire
(molded rib)

Tab on
chassis

Advertising