Freeze sentinel, Fan switch, Auxiliary controls – GE ZONELINE 3200 User Manual

Page 7

Advertising
background image

Switch #6 controls the Freeze
Sentinel. When the switch is

DOWN

,

the Freeze Sentinel automatically
turns on the resistance heater and
fan if the room temperature (sensed
at the unit) drops to approximately
40

°

F. It will turn the heater off when

the temperature reaches about 45

°

F.

The unit leaves the factory with
the Freeze Sentinel in the

DOWN

(on) position.

The Freeze Sentinel helps prevent
plumbing damage in the room due
to sub-freezing temperatures.

If the Freeze Sentinel is set, it is
active as long as power to the
unit is on.

NOTE: The owner is responsible for
checking the Freeze Sentinel switch
and ensuring it is in the desired
setting.

Freeze Sentinel

7

The fan switch #2 is located behind
the room cabinet.
This switch is set at continuous fan
(

DOWN

) at the factory to provide

continuous fan operation in cool
or heat modes. Leaving the switch
in the continuous fan setting allows
continuous circulation of room air
and will result in a more balanced
temperature throughout the room.

If you want the fan to cycle on
and off with the compressor or
with the heater, move the switch
to cycle fan (

UP

).

Fan Switch

UP

DOWN

1 2 3 4 5 6

UP

DOWN

1 2 3 4 5 6

Down—Continuous Fan
Up—Cycle Fan

Auxiliary Controls

The auxiliary controls are located behind the room cabinet on the front of
the unit control box. The factory settings will be in the

DOWN

position. The

owner is responsible for checking switches and ensuring they are in the
desired position.

Auxiliary Controls

UP

DOWN

1 2 3 4 5 6

Freeze Sentinel

CDC (Load Shedding)

UP: Fan cycle
DOWN: Fan continuous

All Time Low Fan

Remote Control
(Class 2)

*All Electric Heat

*Not on Model 2200 Series