Installation instructions, 12 remove duct knockout(s), For 3 – GE JV535 User Manual

Page 12

Advertising
background image

12

REMOVE DUCT KNOCKOUT(S)

If recirculating, non-vented ductless (optional for
JV5 Series models only), see note below and skip to
Step 9 D and proceed. The JV6 Series models cannot
be recirculated.
Using a flat blade screwdriver, remove the appropriate
duct knockout(s)

from the top or back of the hood.

3

1

⁄

4

″ x 10″ Rectangular

vertical discharge.
Remove top rectangular
duct knockout only.

7

″ Round vertical

discharge. Remove semi-
circular duct knockout and top
rectangular duct knockout.

3

1

⁄

4

″ x 10″ Rectangular

horizontal discharge. Remove
rear rectangular duct knockout only.

FOR 3

1

⁄

4

″ x 10″ RECTANGULAR

DUCTED DISCHARGE
INSTALLATIONS ONLY:

Attach exhaust adaptor/damper over knockout
opening with two exhaust adaptor screws. Make sure
damper pivot is nearest to top/back edge of hood.
Remove tape from damper flap.

Up to 1

″ side-to-

side adjustment

Tape

Top/back edge

Exhaust adaptor/damper
(vertical discharge position
shown)

Pivot

FOR 7

″ ROUND VERTICAL

DUCTED DISCHARGE
INSTALLATIONS ONLY:

Re-install the 7

″ round exhaust adaptor with its

screws, removed in Step 2 under the “Prepare the
Hood” section.

6

7

8

7

″ round

exhaust
adaptor

NOTE:

The 7

″ round exhaust adaptor can be installed

up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-center
installations, one end of the duct connector may need
to be trimmed to clear the electrical cable clamp.

NOTE: The 7

″ round damper is not included with

this product. It can be purchased as a kit by calling
800.626.2002. Order kit number JXDA22.

Installation Instructions

NOTE:

The exhaust adaptor/damper can be installed

up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-
center installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.

NOTE:

If the hood is to be installed in a recirculating,

non-vented ductless manner, order charcoal filters,
kit number WB02X11000 for 30

″

hood models, or

kit number WB02X11001 for 36

″

hood models.

These kits can be ordered from your GE supplier.
Skip to Step 9 D and proceed

.