Accessories wiring diagrams – Goodman Mfg RT6100004R13 User Manual

Page 65

Advertising
background image

ACCESSORIES WIRING DIAGRAMS

65

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

COM

XFMR-C

XFMR-R

SPEEDUP

C

NC

M1

K1

R

G

NO

K1

USE COPPER OR ALUMINUM WIRE

EQUIPMENT GROUND

3

5

2

1

4

TR

PC

PU

L1

L2

BL

W BR

SR

PK

G

W

BR

BL

PU

R

BK

R

R

R

BK

BL

BL

R

208/240

24V

BL

R

M6

M5

RS2

W

BR

BL

BL

L1

L2

BK

BK

R

R

Y

Y

Y

M8

M7

BL

BL

BL

EBTDR

HTR2

FL

HTR3

TL

FL

HTR4

TL

8

9

7

6

5

4

3

1

2

Typical Wiring Schematic MBR Blower with Electric Heat.

This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.