Accessories wiring diagrams – Goodman Mfg RT6100004R13 User Manual

Page 68

Advertising
background image

68

ACCESSORIES WIRING DIAGRAMS

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Typical Wiring Schematic ASPF****16A* with Electric Heat.

This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.

BK

BL

BK

L1

L2

BK

BK

HTR1

TL

HTR2

RD

9

8

7

R

WH

BL

PU

TL

BK

5

6

3

4

BK

RD

1

2

WH

BK

L2

L1

BK

RD

RD

RD

BK

R

HTR1 TL

L1

BK

6

8

9

7

2

RD

PU

4

5

3

BK

RD

1

BK

L2

L1

L2

RD

YL

M1

M2

B K

RD

YL

RD

R1

M4

RD

BK

M3

HTR3

TL

HTR2

HTR1

TL

TL

PU

M2

R2

YL

M1

BL

WH

BR

BL

RD

BK

RD

BK

TL

HTR1

BK

HTR4

HTR3

HTR2

BK

RD

9

7

8

L2

L1

L1

L2

2

5

6

3

4

1

RD

M1

YL

BK

M2

BL

WH

6

BL

RD

BK

YL

8

9

7

M6

M5

M3

R1

M4

RD

PU

M7

R2

M8

BL

TL

TL

TL

YL

BL

RD

BK

RD

BL

BR

4

5

3

2

BK

1

ONE (1) ELEMENT ROWS

TWO (2) ELEMENT ROWS

THREE (3) ELEMENT ROWS

FOUR (4) ELEMENT ROWS

FL

M1

M2

FL

FL

M1

M2

M3

M4

FL

FL

FL

FL

FL

FL

FL

USE COPPER OR ALUMINUM WIRE

COPPER OR ALUMINUM

POWER SUPPLY

(SEE RATING PLATE)

USE MIN. 75°C FIELD WIRE

EQUIPMENT GROUND

BL

EM

RD

BL

5

BK

C

BK

PLF

BK

1

RD

2

3

240

24V

4

1

2

3

TR

RD

SEE
NOTE 4

BL

BR

4

5

WH

6

7

89

PLM

GRD

1

BK

2

3

RD

L2

L1

4

5

6

7

8

9

0140A00034

4) Brown and white wires are used with Heat Kits only.

PLM

PLF

TR

FACTORY WIRING

FIELD WIRING

1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts.
2) See composite wiring diagrams in installation instructions

for proper low voltage wiring connections.

Notes:

DELAY RELAY

RELAY

EVAPORATOR MOTOR

ELECTRONIC BLOWER TIME

TERMINAL BOARD

R

EM

EBTDR

TB

BK
RD

BL

YL

BLUE

BLACK
RED
YELLOW

COMPONENT CODE

BROWN

PURPLE

GREEN

PU
BR

GR

FEMALE PLUG CONNECTOR
MALE PLUG CONNECTOR

TRANSFORMER

HIGH VOLTAGE
LOW VOLTAGE

HIGH VOLTAGE
LOW VOLTAGE

PLF

2

COLOR CODE

TR

6

5

PLF

4

4

24V

5

SEE NOTE 1

1

2

3

EM

WIRING CODE

208/240 VOLTS

1

1

PLF

PLM

L1

PLM

2

L2

IF REPLACEMENT OF THE ORIGINAL WIRES

SUPPLIED WITH THIS ASSEMBLY IS NEC ESSARY,
USE WIRE THAT CONFORMS TO THE
NATIONAL ELECTRIC CODE.

SEE NOTE 1

FL

FU SE LIN K

TL

THERMAL LIMIT

HTR

HEAT ELEMENTS

CR

CONTROL RELAY

TERMINAL BLOCK SHOWN

FOR 50HZ MODELS ONLY

3) Confirm speed tap selected is appropriate for application. If speed tap needs

to be changed, connect red wire from terminal 4 of CR relay to appropriate tap
at TB

MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.

KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.

NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER

WHITE

WH

A

B

1

7

4

CR

R C G W1 W2

Y2

Y1

O

SEE NOTE 2

2

1

4

3

5

N

C

G

L

4

1

3

2

5

DH

XFMR-C

C

R

EBTDR

XFMR-R

RD

RD

BL

BL

BL

BL

BR

WH

BL

RD

RD

COM

NO NC

G

GR

RD

RD

BL

GR

GR

RD

RD

RD

BL

BK

RD

SEE
NOTE 3

C L G N

W2

R

W1

C G

4

Y1

O

Y2

1

DH

3

2

5

B

A

NO NC

G

C

XFMR-C

COM

EBTDR

XFMR-R

R

1

C

EM

2

4

3

5

7

4

CR