Gas Connection

Before connecting the appliance, please check

whether the local connection conditions such as
gas type and gas pressure match the appliance
settings.

Make sure the gas supply is turned off at the
manual shut-off valve before connecting the
appliance.

The gas connection must be in a location that
permits access to the manual shut-off valve and
which, if applicable, is visible after opening the
door of the cabinet.

SER

VICER INFO ONLY

Connect the gas supply using the

1

/

2

´ ´ U.S.A. elbow

and the fiber gasket supplied with the unit. The
shorter, nontapered thread fits into the threaded nut
on the hob. The longer, tapered U.S.A. thread is for
the incoming gas supply. Vent the gas line, check
for leaks. The gas pressure regulator is supplied
with the unit and comes set for natural gas. To
convert regulator to LP (propane) gas:

Make-Essex Model SX 229 NA-602

1

/

2

PSIG

1. Remove the aluminum cap from the top of the

regulator.

2. Turn the cap over. It will have LP 10 stamped

inside.

3. Replace the cap on the regulator.

Make-Maxitrol Model RV 47 CL

1

/

2

PSIG

1. Remove the aluminum cap from the top of the

regulator.

2. Remove the yellow plastic shaft from the cap by

pushing it sideways until it pops out of the
groove in the cap.

3. Turn the shaft over and push back into the cut-

out in the cap.

4. Replace the cap on the regulator.