Gaggenau KG 291 CA User Manual

Page 28

Advertising
background image

27

Replacing the main burner nozzles of the

normal burner and large burner

•

Detach the safety spring on the supply lines.
Leave the electrode connected. Unscrew the
burners from the trough (Torx T20) and pull off the
burner from both supply lines.

• Carefully pull off both main nozzles together with

the O-ring by hand.

• Check whether the O-rings of the new nozzle

seats are fitted correctly. Fully push nozzles onto
the supply lines.

Note: do not bend supply lines.

• Push the burners onto the supply lines.

Push the safety springs back on.

• Screw the burners back on the trough.

• Loosen the locking screw and adjust the air

regulation bush according to the nozzle table.
Tighten the locking screw.

See table on page 20-21

for details of nozzle settings.

outer main nozzle

inner main nozzle