Dia14.b, Dia14.l dia14.m, Dia14.k – GE ZVB36 User Manual

Page 10: Dia14.n, Installation preparation, Duct fittings

Advertising
background image

10

Installation preparation

DucT

fITTINGS

Use 3-1/4" x 10"

duct. It can

transition to 6"

round.

Total

Equivalent Quantity

Equivalent

Duct Piece

Dimensions

Length*

Used

Length

1 ft.

6" round,

(per foot

straight

length)

1 ft.

3-1⁄4" x 10"

(per foot

straight

length)


6"

90° elbow

12 ft.


6"

45° elbow

7 ft.


3-1⁄4" x 10"

90° elbow

14 ft.


3-1⁄4" x 10"

45° elbow

8 ft.


3-1⁄4" x 10"

90° flat elbow

33 ft.

6" round

to 3-1⁄4" x 10"

transition

2 ft.

3-1⁄4" x 10"

round to 6"

transition

2 ft.

6" round to

3-1⁄4" x 10"

transition

90° elbow

4 ft.

3-1⁄4" x 10" to 6"

round transition

90° elbow

4 ft.

6" round

wall cap

with damper

24 ft.

3-1⁄4" x 10"

wall cap

with damper

24 ft.


6" round

roof cap

33 ft.

Total Duct Run

Use this chart to

compute maximum

permissible lengths

for duct runs to

outdoors.

NoTe: Do not exceed

maximum permissible

equivalent lengths!

Downdraft Vent:

150' maximum

equivalent length

flexible ducting:

If flexible metal

ducting is used, all the

equivalent feet values

in the table should be

doubled. The flexible

metal duct should be

straight and smooth

and extended as much

as possible.

DO NOT use flexible

plastic ducting.

*Actual length of straight duct plus duct fitting

equivalent. Equivalent length of duct pieces is based

on actual tests conducted by GE Evaluation Engineering

and reflect requirements for good venting performance

with any downdraft cooktop.

NoTe: Any home

ventilation system,

such as a cooktop with

a downdraft exhaust

mechanism, may

interrupt the proper

flow of combustion air

and exhaust required

by fireplaces, gas

furnaces, gas water

heaters and other

naturally vented

systems. To minimize

the chance of

interruption of such

naturally vented

systems, follow the

heating equipment

manufacturer’s

guidelines and safety

standards such as

those published by

NFPA and AShRAE.