Cleaning nozzle and venturi assembly, About the water softener system, Cleaning the nozzle and venturi assembly – GE PROFILE PERFORMANCE SERIES PNSF39Z01 User Manual

Page 14

Advertising
background image

14

About the water softener system.

Cleaning the Nozzle and Venturi Assembly

A clean nozzle and venturi is needed for the water softening system to work properly. This small unit
makes the suction to move brine from the salt storage area to the resin tank during regeneration.
If it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get
hard water.

To get to the nozzle and venturi, remove the water softening system top cover. Be sure the water
softening system is in service cycle (no water pressure at nozzle and venturi). Then, while holding
the nozzle and venturi housing with one hand, remove the cap. Lift out the screen support and
screen, then the nozzle and venturi. Wash and rinse the parts in warm water until clean. If needed,
use a small brush to remove iron or dirt. Also check and clean the gasket.

NOTE: Some models have a small flow plug located in the nozzle and venturi, and/or a small cone
shaped screen in the housing. Be sure to check and clean these parts, if your model is so equipped.

Carefully replace all parts in the correct order. Lightly lubricate the o-ring seal with clean silicone
grease or petroleum jelly and place in position. Install and tighten the cap, by hand only. Do not
over-tighten the cap.

IMPORTANT: Be sure small holes in the gasket are centered directly
over the small holes in the nozzle and venturi housing.

*Install with numbered side up, concave side down.

Cap

O-ring seal

Screen support

Screen

Screen

Nozzle & Venturi

Nozzle & Venturi housing

Gasket

*Flow plug

*Flow plug

Advertising