Problem

Possible Causes

What To Do

Salty tasting water

Insufficient backwash and

•Increase backwash time. See the Service: Regeneration

after installation

rinse time

and Heavy Duty Backwash section.

Low water pressure

•Check pressure; should be minimum 20 psi.

Restricted drain hose

•Clean and reconnect hose.

Resin beads showing

Cracked distributor

•Call for service.

up in drinking water
and sink

Sounds you might hear

Running water from the unit into

•This is normal.

a drain

Water has air bubbles

Air in system after installation

•Will go away after it runs for a while.

and is cloudy

Error Code on control

Wiring may have worked loose in

•Unplug transformer.

control

•Remove control cover, release clips on side.

•Check for loose/incorrect wiring connections to electronic

board or switch. Reconnect as required.

•Reassemble control cover.

•Plug in Transformer.

•Wait six minutes for Error Code to reappear.

•If Error Code reappears call for service.