About water softener system, Data, Feature/service: automatic electronic diagnostics – GE PROFILE PERFORMANCE SERIES PNSF39Z01 User Manual

Page 16: Feature: other data displays

Advertising
background image

The timer computer has a self-diagnostic function for the electrical system (except input power and
water meter). The computer monitors the electronic components and circuits for correct operation.
If a malfunction occurs, an error code appears in the timer display.

The chart on Error Codes shows the error codes that could appear and possible defects for each code.
While an error code is displayed, the TOUCH or HOLD and DATA buttons remain operable so you can
perform the Manually Initiated Electronic Diagnostics.

About water softener system.

16

Feature/Service: Automatic Electronic Diagnostics

By continuing to press the DATA button, you can scan through four displays of operational
information. This data appears in the bottom portion of the display area.

REMAINING CAPACITY —

This is the percentage of water softening capacity remaining.

Immediately after a regeneration, 100% shows. As water is used, the percentage decreases until the
next regeneration. During regenerations, the percentage increases.

NOTE: Zero (%) shows until after the first regeneration begins, after connecting to electrical power.

FLOW RATE, GPM—

When using soft water, this display shows the flow rate passing through

the softener (in gallons per minute). Zero shows if water is not passing through the softener.

GALLONS TODAY—

Each day, beginning at midnight, the timer keeps a running count of the

total gallons of water that have passed through the softener.

AVG. DAILY GALLONS—

The figure displayed is the average gallons of water used by the

household each day over the past seven day period.

NOTE: If preferred, you can set the timer to show the reading in liters instead of gallons. If GALLONS
TODAY
or AVG. DAILY GALLONS exceeds 1999, a (x10) indicator appears; this means you must multiply
the number shown by ten.

Feature: Other Data Displays

To remove an error code: (1) Unplug transformer.

(2) Correct defect.
(3) Plug transformer in.
(4) Wait for at least 6 minutes. The error code will return if the reason

for the error code was not corrected.

DATA

REMAINING CAPACITY
FLOW RATE GPM
GALLONS TODAY
AVG. DAILY GALLONS

WATER MANAGEMENT SYSTEM

AVG. DAILY GALLONS

WATER MANAGEMENT SYSTEM

GALLONS TODAY

WATER MANAGEMENT SYSTEM

GPM

FLOW RATE

CAPACITY

%

WATER MANAGEMENT SYSTEM

ERROR CODE DISPLAYED ERR 01

ERR 02

ERR 03

ERR 04

ERR 05

POSSIBLE DEFECT

• motor

• position

• motor

• position

• timer

inoperative

switch

inoperative switch

or

(PWA)

or wiring

wiring

harness

harness

• wiring harness • timer

• timer

• timer

or connection

(PWA)

(PWA)

(PWA)

to switch

• position switch

• timer (PWA)

Advertising