Important recommendations, Installation instructions, Unpacking and inspection – GE PROFILE PERFORMANCE SERIES PNSF39Z01 User Manual

Page 4

Advertising
background image

Read entire manual. Failure to follow all guidelines and rules could cause personal injury or
property damage.

Before you begin installation, read these Installation Instructions completely. Then, obtain

all the materials and tools you will need to make the installation. Failure to properly install
the softener voids the warranty.

Check local codes. The installation must conform to them.

In the Commonwealth of Massachusetts, Plumbing Code 248 CMR shall be adhered to. Consult with
your licensed plumber.

Use only lead-free solder and flux for all sweat-solder connections, as required by state and

federal codes.

Connect the softener to the main water supply pipe before or ahead of the water heater.

DO NOT RUN HOT WATER THROUGH THE SOFTENER. Temperature of water passing through
the softener must be less than 120° F.

Use care when handling the softener. Do not turn upside down, drop, drag, or set on

sharp protrusions.

Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi,

nighttime pressure may exceed the maximum. Use a pressure reducing valve if necessary.
(Adding a pressure reducing valve may reduce the flow.)

The softener works on 24 volt-60 Hz electrical power only. Be sure to use the included

transformer. Be sure the electric outlet and transformer are in an inside location to protect
from wet weather.

See Where to Install the Softener section for more details.

WARNING: Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. The water should be tested
periodically to verify that the system is performing satisfactorily.

Small parts remaining after the installation could be a choke hazard. Discard safely.

4

Installation instructions.

CAUTION: Certain plumbing skills are needed for installation. If you are unsure about any
part of the installation of this product, consult a professional plumber.

Unpacking and Inspection

Be sure to check the entire softener for any shipping damage or parts loss. Also note damage
to the shipping cartons. Contact the transportation company for all damage and loss claims.
The manufacturer is not responsible for damages in transit.

Small parts, needed to install the softener, are on a skin-packed cardboard piece. To avoid loss
of the small parts, keep them on the skin-pack until you are ready to use them.

Important Installation Recommendations

Advertising