1 description – GE MULTILINK 1601-9026-A3 User Manual

Page 17

Advertising
background image

QUICKSTART GUIDE

MULTILINK ETHERNET COMMUNICATIONS SWITCH – QUICKSTART GUIDE

13

4 Connecting a Management Console Terminal to

the Unit

4.1 Description

Use a DB-9 to DB-9 null-modem cable (ML2400/ML1600) or RJ45 to DB-9 null-modem
cable (ML1200/ML800) to connect the Unit console port to the a PC.

NOTE

Note

Console cables may be purchased as a separate items. They are not included with the
Unit.

4.1.1 ML2400/ML1600

FIGURE 10: Unit console port

The pin assignment for the console port are indicated in the following table.

This information enables a management station (PC or console terminal) to connect
directly to the switch console using a straight-through serial cable.

Table 1: Console port pin assignment

Pin

Signal

Description

1

CD

Carrier detect (not used)

2

RXD

Receive data (input)

3

TXD

Transmit data (output)

4

open

not used

5

GND

Signal ground

6 to 9

open

not used

754736A1.CDR

Advertising