Alarms included: low inlet pressure, high amp draw, high / low pH

1.5

Specifications for E-Series Machines

1.5.1

Feed Water Requirements

Table 1.1

Feed Water Requirements

1.5.2

Permeate (Product Water) Flow Rate

Stated on the serial number label (assumes no permeate back pressure,
2000 mg/L TDS maximum feed concentration, and rated temperature).

To estimate permeate output with back pressure, use the formula below:

Permeate Back Pressure:

Maximum: 80 psig (5.5 barg)

Permeate Outlet:

1-inch FNPT

7

Temperature

Inlet Pressure

Chlorine

(continuous feed)

Operating pH

Pre-filter

Inlet Connections

35° - 77°F (2° - 25°C) Not to exceed
85°F (29°C) unless specifically
designed for higher temperatures

Minimum: 30 psig (2.1 barg)
Maximum: 60 psig (4.1 barg)

For Osmo HR(PA) membrane ele-
ments: 0 ppm

Soft water [less than 1 grain per gal-
lon: 3.0 - 10.0 (gpg) or 17 mg/L hard-
ness], acceptable pH: 5.5 - 6.0

5 micron HYTREX cartridge
(part number on machine label)

1.5-inch FNPT*

(Permeate Flow on Label) x [(Operating Pressure) - (Permeate Back Pressure)]

Operating Pressure

*

FNPT: Female National Pipe Thread