27

SYMPTOM

Low permeate flow rate

(continued)

Low concentrate flow rate,

normal or higher than

normal pressure

Pressure does not drop when

concentrate valve opened

POSSIBLE CAUSES

Dirty or fouled membrane

elements

Operating on cold water less

than 55ºF (13ºC)

Membrane elements installed

backwards or damaged

concentrate seal

Flow meter inaccurate

Concentrate valve plugged

Concentrate outlet line restricted

Flow meter inaccurate

Dirty concentrate valve

REMEDIES

Flush and clean the membrane

elements.

Install a hot/cold feed water

tempering valve if more perme-

ate flow is needed. Operate

with a feed water temperature of

72º - 77ºF (22º - 25ºC).

Install membrane elements in

the direction of fluid flow.

Flush and clean the machine

immediately. Membrane ele-

ments with damaged concentrate

seals should be cleaned and may

be returned for repair.

Check the flow rate manually

with a stopwatch and calibrated

container.

Remove the concentrate valve

stem and/or disassemble the

plumbing. Clean the valve.

Examine the concentrate line for

obstructions or kinks, repair or

replace the tubing.

Check the flow rate manually

with a calibrated container.

Disassemble and clean the

plumbing to the valve.

TROUBLESHOOTING GUIDE