Installation instructions – GE 164D4290P393 User Manual

Page 8

Advertising
background image

DUCT

EQUIVALENT NUMBER

PIECES

LENGTH

x USED

= TOTAL

3

1

4

″x 10″

1 Ft.

x ( )

=

Ft.

Rect.,
straight

7

″ Round,

1 Ft.

x ( )

=

Ft.

straight

6

″ Round,

1 Ft.

x ( )

=

Ft.

straight

3

1

4

″x 10″

8.5 Ft.

x ( )

=

Ft.

Rect. 90°
elbow

3

1

4

″x 10″

7 Ft.

x ( )

=

Ft.

Rect. 45°
elbow

3

1

4

″x 10″

24 Ft.

x ( )

=

Ft.

Rect. 90°
flat elbow

3

1

4

″x 10″

45 Ft.

x ( )

=

Ft.

Rect.

(7 ft. w/o

wall cap

damper)

x ( )

=

Ft.

with
damper

3

1

4

″x 10″

4.5 Ft.

x ( )

=

Ft.

Rect. to
6

″ round

transition

3

1

4

″x 10″

11.5 Ft.

x ( )

=

Ft.

Rect. to
6

″ round

transition
90° elbow

6

″ Round,

8 Ft.

x ( )

=

Ft.

90° elbow

6

″ Round,

6.5 Ft.

x ( )

=

Ft.

45° elbow

Subtotal column 1

=

Ft.

8

WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH

DUCT

EQUIVALENT

NUMBER

PIECES

LENGTH

x USED

= TOTAL

6

″Round 34 Ft.

x ( )

=

Ft.

wall cap

(6 ft. w/o

with

damper)

x ( )

=

Ft.

damper

6

″ Round 30 Ft.

x ( )

=

Ft.

roof cap

6

″ Round 5.5 Ft.

x ( )

=

Ft.

to
3

1

4

″x 10″

rect.
transition

6

″ Round 14.5 Ft.

x ( )

=

Ft.

to
3

1

4

″x 10″

rect.
transition
90° elbow

7

″ Round, 8 Ft.

x ( )

=

Ft.

90° elbow

7

″ Round, 6.5 Ft.

x ( )

=

Ft.

45° elbow

7

″ Round 34 Ft.

x ( )

=

Ft.

wall cap

(6 ft. w/o

with

damper)

x ( )

=

Ft.

damper

7

″ Round 30 Ft.

x ( )

=

Ft.

roof cap

7

″ Round 5.5 Ft.

x ( )

=

Ft.

to
3

1

4

″x 10″

rect.
transition

7

″ Round

14.5 Ft.

x ( )

=

Ft.

to
3

1

4

″x 10″

rect.
transition,
90° elbow

Subtotal column 2

=

Ft.

Subtotal column 1

=

Ft.

Total ductwork

=

Ft.

Installation Instructions

MAXIMUM DUCT LENGTH:

For satisfactory air

movement, the total duct length of a 3

1

4

″ x 10″

rectangular, 6

″ or 7″ diameter round duct should

not exceed 65 equivalent feet.

Advertising