Grizzly G0705 User Manual

Page 15

Advertising
background image

Model G0705 (Mfg. since 09/09)

-13-

4. remove the screws that secure the brass

contactor mounting plate to the back of the
electrical box, then pull the contactors out
to access the gray tab shown in

figure 7.

pull outward on the gray tab to release each
contactor from the mounting plate.

5. install the two 110v contactors from the

Model g0705 110v Conversion Kit in place
of the contactors you removed in

step 4.

6. replace the wires you removed in step 3

to the corresponding terminals on the 110v
contactors. the wiring is the same for 110v
and 220v. refer to

section 8: Wiring

starting on

page 45 for detailed wiring dia-

grams.

7. locate the indicator lamp shown in figures 4

&

5. disconnect the two wires from its termi-

nals, then remove the lamp.

8. install the 110v indicator lamp from the

Model g0705 110v Conversion Kit in place
of the lamp you removed in

step 7.

9. Connect the wires you removed in step 7 to

the corresponding terminals on the 110v indi-
cator lamp. the wiring is the same for 110v
and 220v.

figure 7.

Contactor release tab location.

gray tab

Neutral

Hot

Ground

110 VAC

5-20 Plug

(As Recommended)

Hot

Hot

Ground

6-15 Plug

(As Recommended)

G

Ground

PE

V2

V1

U2

U1

U2

V1

V2

Z1

W1

Z2

W2

U1

U2

V1

V2

Z1

W1

Z2

W2

U1

To Electrical Box

Start

Capacitor

150 MFD

250 VAC

Run

Capacitor

20 MFD

450 VAC

110V Terminal

Block Jumper

Position.

(Wire positions

are the same for

110V/220V)

To Electrical Box

Cord Rewired for 110V

Motor 220V

figure 8.

Jumper positions on terminal block.

terminal Block

220v Jumper

location

10. locate the terminal block located in the motor

junction box, shown in

figure 8.

Mounting plate

Jumpers Moved

for 110v