23

IO-242C

05/05

5. Turn OFF gas to furnace at the manual shutoff valve and

disconnect manometer. Reinstall plug before turning on
gas to furnace.

6. Turn OFF any unnecessary gas appliances started in step

3.

W

HITE

-R

ODGERS

36G22 G

AS

V

ALVE

The line pressure supplied to the gas valve must be within the
range specified below. The supply pressure can be measured at
the gas valve inlet pressure tap or at a hose fitting installed in the
gas piping drip leg. The supply pressure must be measured with
the unit OFF. To measure inlet pressure, use the following
procedure.

Pressure Regulator

Adjustment

(Under Cap Screw)

Gas Valve

On/Off

Selector

Switch

INLET

OUTLET

Inlet Pressure

Tap

Outlet Pressure

Tap

White-Rodgers Model 36G22

1. Turn OFF gas to furnace at the manual gas shutoff valve

external to the furnace.

2. Using 3/32 hex wrench, loosen inlet pressure tap screw

one turn.

3. Connect a 5/16 inch hose and calibrated water manometer

to the gas valve inlet pressure tap. The hose should overlap
the tap by 3/8 inch.

4. Turn ON the gas supply and operate the furnace

5. Leak test. Using a leak detection solution or non-chlorine

soap suds, check for leaks at hose connection. Bubbles
forming indicate a leak. SHUT OFF GAS AND FIX ALL LEAKS
IMMEDIATELY BEFORE PROCEEDING TO NEXT STEP!

6. Measure furnace gas supply pressure. Supply pressure

must be within the range specified in the Inlet Gas Supply
Pressure
table.

If supply pressure reading differs from the table, make
necessary adjustments to pressure regulator, gas piping
size, etc., and/or consult with local gas utility.

Natural Gas

Minimum: 5.0" w.c.

Maximum:10.0" w.c.

Propane Gas

Minimum: 11.0" w.c.

Maximum:13.0" w.c.

Inlet Gas Supply Pressure

7. Turn OFF gas to furnace at the manual shutoff valve and

disconnect manometer and hose. Reinstall plug before
turning on gas to furnace.

8. Seal pressure port. Tighten inlet pressure tap screw

clockwise 7 in-lbs. minimum.

9. Retest for leaks. If bubbles form, shut down gas and fix

leaks immediately.

10. Turn valve switch ON.

G

AS

S

UPPLY

P

RESSURE

M

EASUREMENT

CAUTION

T

O PREVENT UNRELIABLE OPERATION OR EQUIPMENT DAMAGE, THE INLET

GAS SUPPLY PRESSURE MUST BE AS SPECIFIED ON THE UNIT RATING PLATE

WITH ALL OTHER HOUSEHOLD GAS FIRED APPLIANCES OPERATING.

W

HITE

-R

ODGERS

36F22 G

AS

V

ALVE

The line pressure supplied to the gas valve must be within the
range specified below. The supply pressure can be measured at
the gas valve inlet pressure tap or at a hose fitting installed in the
gas piping drip leg. The supply pressure must be measured with
the burners operating (see picture above). To measure the gas
supply pressure, use the following procedure.

With Power and Gas Off:

1. Connect a water manometer or adequate gauge to the “inlet

pressure tap” of the gas valve.

As an alternative method, inlet gas pressure can also be
measured by removing the cap from the drip leg and
installing a predrilled cap with a hose fitting.

With Power and Gas On:

2. Put furnace into heating cycle and turn on all other gas

consuming appliances.

If operating pressures differ from the Inlet Gas Supply Pressure
table below, make necessary pressure regulator adjustments,
check piping size, etc., and/or consult with local utility.

Gas Line

Gas
Shutoff
Valve

Gas Line
To Furnace

Drip Leg Cap
With Fitting

Manometer Hose

Manometer

Open To
Atmosphere

Measuring Inlet Gas Pressure (Alternate Method)

3. Turn ON the gas supply and operate the furnace and all

other gas consuming appliances on the same gas supply
line.

4. Measure furnace gas supply pressure with burners firing.

Supply pressure must be within the range specified in the
table.

Natural Gas

Minimum: 5.0" w.c.

Maximum:10.0" w.c.

Propane Gas

Minimum: 11.0" w.c.

Maximum:13.0" w.c.

Inlet Gas Supply Pressure

If supply pressure differs from table, make the necessary
adjustments to pressure regulator, gas piping size, etc., and/or
consult with local gas utility.