Gms8/gds8/ghs8, Wiring diagram for – Goodman Mfg GHS8 User Manual

Page 31

Advertising
background image

31

IO-242C

05/05

Wiring Diagram for

GMS8/GDS8/GHS8

TO 115VAC/ 1

Ø /60 HZ POWER SUPPLY WITH

JUNCTION

BOX

GND

LINE-N

LINE H

DOOR SWITCH

PROPERLY POLARIZED AND GROUNDED.

SERVICING.WIRING TO UNIT MUST BE

WARNING:DISCONNECT POWER BEFORE

CAP

BK (

HI)

AUXILARY

INTEGRATED

24 VAC

FUSE

6

3

9

12

HUMIDIFIER

TWIN

R

5

4

1

2

8

7

11

10

O

LED

DIAGNOSTIC

LINE-H XFMR-H HEAT-H COOL-H

BLOWER HEAT

DIP SWITCHES

OFF DELAY SELECTOR

CONTROL MODULE

(SECONDS)

BK

115 VAC HOT AN D PARK TERMINALS

FROM FACTORY

2

1

GN

*

PU

ON

90

120

ON

ON

OFF

ON

180

150*

AS SHIPPED

OFF

OFF
OFF

XFMR

BK

BK

BK

115V

24V

1

15 VA

C
N

E

U

T

RA
L

BR

LIMITS

W

W (

N)

R (LOW

)

O

(ME

D LO

W)

BL (

MED)

BL
OWER

CICU

LATO

R

24V THER

MOS

T

AT

C

ONNE

CTIO

NS

RO2 (11)

LIMIT

GND (8)

HUMIDIFIER

XFMR (6)

GND

G

C

W

Y

TO
MICRO

R

MV (12)

MVC (9)

AUXILIARY
LIMIT CONTROLS

PS (10)

PSO (4)

HLI (7)

HLO (1)

CONTROL MODULE

INTEGRATED

NO

SWITCH

PRESSURE

ID BLOWER

VALVE

M1

GAS

C2

C

AUTO RESET
PRIMARY

MANUAL RESET ROLLOUT
LIMIT CONTROL(S)

115 VAC

FLAME SENSOR

FP (2)

XFMR-H

XFMR (3)

RO1 (5)

24 VAC

HOT SURFACE

IGNITER

HUM-H

IN
TEGR

ATED

CON

TROL

MOD

ULE

BR

BR

COOL-H

HUMIDIFIER

IGN

IND

ID
BLWR

CIRCULATOR

HEAT-H

COO

L

HE

AT

BLWR

TRANSFORMER

40 VA

CONTROL

XFMR-N

INTE

GRAT

ED CO

NTRO

L
MO
DULE

HUM-N

CIR-N

B14933255 REV.00

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

ON SOME MODELS

HUMIDIFIER

24 VAC

INDUCED DRAFT

BLOWER COMPARTMENT

BURNER COMPARTMENT

REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE

"PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.

BEFORE CONNECTING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE PLACED ON

4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER

INTEGRATED CONTROL

INTERNAL TO

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

BLOWER

GAS VALVE

PRIMARY LIMIT

BK

GN

W

IGNITER

SURFACE

HOT

M1

PU

W

R

W

15 PIN PLUG

C

NO

SWITCH

PRESSURE

BR

C2

SENSOR

FLAME

BK

W

ROLLOUT LIMITS

CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY

SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)

7 FLASHES = LOW FLAME SIGNAL

5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

4 FLASHES = OPEN HIGH LIMIT

3 FLASHES = PRESSURE SWITCH STUCK OPEN

2 FLASHES = PRESSURE SWITCH STUCK CLOSED

STEADY ON = NORMAL OPERATION

OFF = CONTROL FAILURE

5

1 FLASH =

0

1

2

3

4

PU

6 FLASHES =

OPEN ROLLOUT

COLOR CODES:

PU PURPLE

O ORANGE

Y YELLOW

6

7

C

BK BLACK

GN GREEN

BR BROWN

PK PINK

R RED

GY GRAY

BL BLUE

W WHITE

PU

RATING OF AT LEAST 105ºC. USE COPPER CONDUCTORS ONLY.

NOTES:

OVERCURRENT PROTECTION DEVICE

JUNCTION BOX

MUST BE

WARNING:

EAC-H

SWITCH

WIRING TO UNIT

BEFORE SERVICING.

DISCONNECT POWER

LINE-H

DOOR

ELECTRONIC

AIR CLEANER

AND GROUNDED.

POLARIZED

PROPERLY

L

GND

LINE-N

EAC-N

DISCONNECT

N

SWITCH (TEMP.)

FIELD SPLICE

SWITCH (PRESS.)

PROT. DEVICE

OVERCURRENT

EQUIPMENT GND

TERMINAL

JUNCTION

HI VOLTAGE FIELD

HI VOLTAGE (115V)

LOW VOLTAGE FIELD

LOW VOLTAGE (24V)

PLUG CONNECTION

IGNITER

FIELD GND

IND-N

IGN-N

OVERCURRENT PROTECTION

POWER SUPPLY WITH

TO 115 VAC/ 1/60HZ

DEVICE

W

BK

SWITCH LOCATED IN BLOWER
COMPARTMENT ON SOME MODELS

R

R

R

BL

Y

Y

R

BL

BL

PU

Y

Y

BR

O

o

o

Y

Y

RR

W

W

W

Y

o

BK

Y

BR

W

G

C

W

Y

R