Iring, Iagram, Cont – Goodman Mfg CPH COMMERCIAL SS-CPH90-150 User Manual

Page 33: Roduct, Pecifications, Arning

Advertising
background image

32

www.goodmanmfg.com

SS-CPH90-150

SS-CPH90-150

www.goodmanmfg.com

33

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

iring

d

iagram

— CPH150***3B/ 4B/ 7B*** (

Cont

.)

R

EBTDR

BC

R

HVDR

Y

RVC1

SEE UNIT RATING PLATE FOR TYPE AND SIZE

5

OF OVER CURRENT PROTECTION

4

BLOWER CONTACTOR

COMPRESSOR CONTACTOR

CONDENSER MOTOR

CONDENSER MOTOR CONTACTOR

COMPRESSOR

DEFROST CONTROL

DEFROST THERMOSTAT

ECONOMIZER

ELECTRONIC BLOWER TIME DELAY

EVAPORATOR MOTOR RELAY

RELAY

EVAPORATOR MOTOR

FAN CAPACITOR

EQUPIMENT GROUND

HIGH PRESSURE SWITCH

HIGH VOLTAGE DEFROST RELAY

LOW PRESSURE SWITCH

LOW VOLTAGE DEFROST RELAY

POWER DISTRIBUTION BLOCK

FEMALE PLUG / CONNECTOR

REVERSING VAVLE COIL

RUN CAPACITOR FOR

CONDENSER FAN

TERMINAL BLOCK (24V SIGNAL)

TRANSFORMER

LVDR

W2

DFT

R

DFT1

C

BC

CC

CM

CMC

COMP

DC

DFT

ECON

EBTD

EMR

R

EM

FC

GND

HPS

HVDR

LPS

LVDR

PB

PLF

RVC

RCCF

TB1

TR

6

COMPONENT LEGEND

R

R

C

208-240/460/575/3/60 0140L00547 REV. B

P

L

F

1

G

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND

TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)

USE COPPER CONDUCTOR ONLY.

2. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR

COMPARTMENT. REMOVE MALE PLUG AND ATTACH

FEMALE PLUG TO THE ECONOMIZER ACCESSORY.

4. FOR TWO STAGE OPERATION REMOVE W1 TO W2

JUMPER WIRE.

EBTDR

CC1

DC

EBTDR

TB1

HPS1

LPS1

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

HPS2 LPS2 CC2

C

W1

W2

G

Y1

THERMOSTAT

O

Y

Y2

R

++

GR GREEN

WIRE CODE

BL BLUE

PU PURPLE

PK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW

YL/PK YELLOW WITH

PINK STRIP

BL/PK BLUE WITH

PINK STRIP

S1

S2

CMC

RCCF

CMC

RCCF2

CM2

T2

CC2

T3

T1

COMP2

CC2

T1

CC2

T2

CMC

BC

BC

CC1

L2

T3

COMP1

F

SUPPLY VOLTAGE

CM1

EM

L1

CC1

T1

C

CC1

L3

208-240V

OR APPROPRIATE

INPUT VOLTAGE

208-240/460/575/3/60

T2

3

1

TR

24V

8

7

9

OR

O

O

BL

Y1

GR

PK

TB1

W1

R

G

C

R

2 STAGE COOLING

Y/Y2

YL

G

C

WH

Y2

Y1

STAT

W1

RD

THERMOSTAT

FIELD WIRING

W2

BR

W2

SEE NOTE 4

SSHR

NO

NC

PLF2

9

7

8 5

6

4

3
2

1

SEE NOTE 3

O

SSHR

SECOND STAGE HEATER RELAY

5. FOR 208V OPREATION, MOVE BLACK WIRE FROM

TERMINAL 3 TO TERMINAL 2 ON 240V TRANSFORMER.

T2

DR

NO

NC

DR

DEFROST RELAY

BC

DFT2

R

RVC2

Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.

W

arning

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.