Servicing instructions, Replacing parts, Electrode 7. thermocouple 4 6 – Stovax GAZCO Linea Balanced Flue Convector Fire User Manual

Page 18: Pilot injector

Advertising
background image

18

4.7

Reassemble in reverse order and replace the pilot gasket

with a new one.

4.8

Check for gas leaks.

5.1

To gain access to the pilot pipe, it is easier if the

thermocouple is removed first. To do this follow section 7.

5.2

Undo the pilot pipe from the top of the gas valve and from

under side of the pilot burner. See diagram 5 arrow B.

5.3

Remove the pipe and the injector will drop out from the

burner. take care not to lose or damage the injector.

5.4

To replace the injector reverse the above procedure.

5.5

Check for gas leaks.

6.1

Remove the lower panel. See diagram 6.

SERVICING INSTRUCTIONS

REPLACING PARTS

6.2

Pull the ignition lead off the electrode and undo the

retaining nut. See diagram 7.

6.3

Replace with a new electrode. Do not over tighten the nut

as this could break the new component.

6.4

Replace the ignition lead and the lower cover.

7.1

Remove the lower panel. See diagram 6.

6. ELECTRODE

7. THERMOCOUPLE

4

6

AR1341

7

AR1349

5

AR1343

5. PILOT INJECTOR

B

x

X = LPG 10

NG 15

Advertising