Servicing instructions, Replacing parts, Ignition lead – Stovax GAZCO Linea Balanced Flue Convector Fire User Manual

Page 19: Magnetic safety valve

Advertising
background image

19

7.2

Disconnect the thermocouple from the gas valve. See

diagram 8 arrow C.

7.3

Undo the thermocouple nut in the back of the pilot burner

by half a turn. This will release the thermocouple.

7.4

Disconnect the two leads noting the orientation. The lead

with the red tape on is connected to the thermocouple

spade nearest the gas valve. See diagram 9.

WHEN REPLACING WITH A NEW THERMOCOUPLE

TAKE EXTREME CARE TO BEND THE NEW COMPONENT

TO THE EXACT SHAPE AND TO KEEP THE

CONNECTORS IN THE SAME ORIENTATION.

7.5

When replacing the thermocouple into the pilot burner

ensure the component is pushed fully into the hole. There

is a stop on the thermocouple to set the height.

7.6

Lock the retaining nut just enough to grip the

thermocouple.

7.7

Replace the lower panel.

8.1

Remove the lower panel and pull the ignition lead off the

electrode.

8.2

Locate the ignition lead in the control box situated on the

left-hand side of the appliance and disconnect it. See

diagram 10

8.3

Release the wires from the central white clip and carefully

cut the cable ties. This will release the ignition lead. See

diagram 11.

8.4

Replace with a new lead, replace with new cable ties and

fit the wires back into the clip.

8.5

Fit the cover and ensure no wires are trapped.

9.1

Turn the gas off at the isolation device.

9.2

Remove the lower cover. See diagram 6

8. IGNITION LEAD

SERVICING INSTRUCTIONS

REPLACING PARTS

8

AR1344

10

AR1346

11

AR1344

9

AR1346

9. MAGNETIC SAFETY VALVE

C

4.5

v

4.5

v

Advertising