22

SERVICING INSTRUCTIONS

REPLACING PARTS

In order to change between gas types it will be necessary to
change the following items.

Main Injector
Main Burner
Pilot Injector
Control Valve
Control Box
Thermocouple ( NG to LPG only).
LPG to NG no change).
Data Badge

NOTE: THIS ONLY NEEDS TO BE DONE IF ACCESS IS

TO THE CONTROLS IS RESTRICTED.

14.1 Remove the outer decorative front, refer to the instructions

supplied with the front.

14.2 Remove the lower cover. See diagram 6.
14.3 Disconnect the gas pipe at the isolation device. See diagram

21 arrow B.

14.4 Remove the glass frame. See diagram 22 arrow C.

13. CHANGING BETWEEN GAS TYPES

14. CONTROL BRACKET ASSEMBLY

21

AR1344

14.5 Remove the main burner as described in section 2.
14.6 Remove the injector locknut. See diagram 23.

14.7 Disconnect the touch pad from the harness. See diagram 21

arrow A.

14.8 Disconnect the ignition lead from the electrode.
14.9 Remove the thermocouple. See diagram 21 arrow C.
14.10 Remove the pilot pipe and ensure the pilot injector is kept

safe.

14.11 Remove the two screws securing the control bracket from

under the appliance. See diagram 21 arrow E.

14.12 Tilt the front edge of the bracket down slightly and move

the assembly to the right to disengage the injector. Rotate

the left hand side forward and down to allow the removal

of the injector from the side of the appliance. The assembly

should now be free of the appliance.

14.13 Reassemble in reverse order and check for gas leaks.