User instruction, Battery replacement fire will not light 4 – Stovax GAZCO Linea Balanced Flue Convector Fire User Manual

Page 7

Advertising
background image

7

USER INSTRUCTION

10.1 If the Linea is fitted with a Designio front, access to the

batteries can be achieved by simply dropping the lower

front access cover.

10.2 If the Linea is fitted with a Plano or Vetro front, access to

the batteries can be achieved through the access hole in the

casing below the unit. See diagram 4.

10.3 Remove the top from the plastic battery compartment by

gently depressing the top in the area with the indication

arrow and then sliding off in the direction of the arrow. See

diagram 5.

10.4 Replace the batteries with three "C" size cells ensuring they

are in the correct orientation as shown in the diagram in the

base of the plastic battery holder.

10.5 Replace the top of the battery holder and push back into its

location.

10. BATTERY REPLACEMENT

FIRE WILL NOT LIGHT

4

Does the pilot spark when

using the handset?

Does the pilot spark when

using the touch pad?

Is there any spark

at the pilot?

Does the appliance go

out during use?

Does pilot light then go

out immediately?

Is the low battery indicator

visible on the handset display?

Change the appliance

batteries

Change the handset

batteries

Does it spark only once or

twice and very slowly?

NO

NO

NO

NO

NO

YES

YES

YES

YES

INSUFFICIENT BATTERY POWER

The Copreci control system used on this appliance has a

built-in safety feature which will prevent the appliance from

lighting if there is insufficient battery power. This feature

will also act to turn the appliance off if the battery power

falls below a safe level.
When the battery power falls to a low level, this is indicated

by 10 audible beeps and 10 continuous flashes on the

touchpad LED indicator. This will occur when the ignition is

activated and the batteries should be replaced.
If the appliance will not light, please check the touchpad for

this warning before proceeding further. You may notice a

noise from the control valve when attempting to light the

appliance under these conditions. This is normal and should

not cause concern.