INSTALLATION

Proper placement of the oven will ensure operator

convenience and satisfactory performance. Adequate

clearance must be provided for cleaning, servicing,

and proper operation. (Refer to chart on page 4. for

minimum clearances.)

Electrical Connection

Before attempting the electrical connection, the rating

plate should be checked to confirm that the oven’s

electrical characteristics and the electrical supply are

compatible. The plate is located on the inside surface of

the control panel/body side.
• Attach the appropriate plug to the end of the cord

supplied with the oven.

• Visually inspect all electrical connections. A wiring

diagram is affixed to the inside surface of the control

panel/body side section.

Installation of the wiring must be made in accordance

with local codes, and the National Electrical Code,

ASNI/NFPA 70-1990, or in Canada, the Canadian

Electrical Code in regards to:
1. Switch panel size
2. Overload protection
3. Wire type
4. Wire size
5. Temperature limitations of wires
6. Method of connection, (conduit, cable, etc.)

WATER CONNECTION

It is the responsibility of the purchaser to install and

maintain the water supply to the moisture+ oven. Failure

to provide satisfactory water quality to operate the oven

properly can cause damage to integral components

and void your warranty. This oven must be installed

to comply with the applicable federal, state, or local

plumbing codes.
Water supply connection to the moisture+ is made via

a 1/4” NPTF fitting at the rear of the oven. The ability

to move the oven for service and cleaning may be a

consideration when choosing the type of connection

and supply line to be attached at this fitting.
The moisture+ water delivery system includes a water

pressure regulator that has been pre-set to operate at 10

psi. The water supply must maintain at least 20 psi and a

flow rate of three gallons per minute for proper operation

of the oven’s moisture injection system.

Water Quality

Garland recommends that the supply water be filtered

before it enters the oven’s water delivery system. This

will extend the life of the oven and its water delivery

system components by minimizing particles in typical

tap water sources that cause scaling and buildup of

mineral deposits.
It is recommended that your supply water not exceed

any of the following parameters: 60 PPM total dissolved

solids; 20 ppm alkalinity; 13 ppm silica; 30 ppm chloride;

PH factor of 7.5.
Consult a local water treatment specialist for

recommendations regarding your water supply system

and its use with this oven. The use of highly mineralized,

(‘hard’), water could negatively affect the quality of

products prepared using the oven. The potability of

supply water does not guarantee its suitability for use

with the moisture+.

Drain

Your moisture+ oven has a gravity drain in the left rear

corner of the oven cavity. The drain pipe that exits the

rear of the oven must be directed downward toward the

floor, and should run directly to an open floor drain.

Avoid using flexible hose that could sag or kink, allowing

water to accumulate. The drain must be vented. This

connection must be at least 3/4" NPT, and configured

in accordance with local codes.