Installation instructions, Removal of the log guard, Fitting & removal of firebricks (brunel 1a only) – Stovax 7008Bl User Manual
Page 20
20
INsTAllATIoN INsTRUCTIoNs
The Flue must be installed in accordance with
manufacturers instructions.
Seal Collar with Fire Cement
Self Tapping Screw
Tee
Size
Stovax Part No.
5"
4516
6"
(4616)*
Cap
PR7228
PR7229
600mm min
1000mm max
unsupported
Elbow with access cover
Size
Stovax Part No.
5"
4512
6"*
4612
Flue Pipe 915mm (3ft)
Size
Stovax Part No.
5"
4502
6"*
4602
To chimney connection as detailed in
building regulation
2. ReMoVAl oF THe loG GUARd
2.1 To remove the Log guard:
• Lift Log Guard clear of the supporting brackets
• Rotate to clear the sides of the door opening.
do not use appliance without the log guard in position.
3. FITTING & ReMoVAl oF FIReBRICKs
(BRUNel 1A oNlY)
3.1 Remove the firebricks as part of the routine maintenance.
This can be carried out without the use of tools.
3.2 Allow the appliance to cool fully before removing firebricks.
PR8009
The Flue must be installed in accordance with
manufacturers instructions.
PR7230
Self tappping
screw at rear
Flue Pipe 915mm (3ft)
Size
Stovax Part No.
*5"
4502
6"
4602
Seal flue collar
with Fire Cement
600mm min
1000mm max
unsupported
Elbow with access cover
Size
Stovax Part No.
5"
4512
6"*
4612
Flue Pipe 915mm (3ft)
Size
Stovax Part No.
5"
4502
6"*
4602
To chimney connection
as detailed in building
regulations
PR7226
1.3 Rear flue pipe installation
• Insert a tee into the flue collar
The tee piece is used as cleaning access.
• Lift appliance into position
Take care not to damage the hearth finish.
• Level using adjustable bolts, see picture 1
• Connect tee to the chimney using flue pipe
• Secure with self tapping screw
• Seal the connecting joints
Do not use a 90˚ elbow to make this connection