User instructions, General points, Serial number – Stovax 7008Bl User Manual

Page 4: Air controls

Advertising
background image

4

UseR INsTRUCTIoNs

1. GeNeRAl PoINTs

1.1 Before use of this appliance please read these

instructions fully.

1.2 All local regulations, including those referring to national

and european standards need to be complied with when

installing the appliance.

1.3 Only use for domestic heating in accordance with these

operating instructions.

1.4 You must burn only approved fuels. Do not use with liquid

fuels or as an incinerator.

1.5 Appliance surfaces become very hot when in use. Use

a suitable fireguard if young children, elderly or infirm

persons are present.

Stovax offer firescreens, sparkguards and hearthgate systems

for protection*. Your Stovax dealer can advise you about

these products.

1.6 Do not place photographs, TV’s, paintings, porcelain or

other combustible items on the wall or near the appliance.

Exposure to hot temperatures will cause damage.

1.7 Extractor fans or cooker hoods must not be placed in the

same room or space as this can cause appliance to emit

fumes into the room.

1.8 Do not obstruct inside or outside ventilation required for

the safe use of this appliance.

1.9 Do not make unauthorised changes to the appliance.

1.10 The chimney must be swept at least once a year.

See Section 12

1.11 do not connect, or share, the same flue or chimney

system with another appliance.

seRIAl NUMBeR

1.12 This number is required when ordering spare parts or

making warranty claims.

It is found on the appliance data plate, this can be read

with a mirror. See Diagram 1

Airwash

Control

Main Door

Primary Air

Control

Cleanburn

Combustion

Control

(Not 1A)

Main Door Catch

Ashdoor

Ashlip

PR7209

AIR CoNTRols

Stovax appliances have air systems providing cleaner

burning, and greater efficiency and control,

See Diagram 2

1) Airwash - air drawn over the window cleans the glass.

The source of Primary Combustion air when burning wood.

2) Primary Air - for use with solid fuel and initially with

wood fires.

3) Cleanburn - Secondary air ( Brunel 2 & 3 CB only*)

is channelled from an inlet beneath the stove and

preheated through a heat exchanger to combust unburned

hydrocarbons, providing a cleaner and more efficient burn.

* Brunel 1A is smaller so the Airwash provides enough

combustion air for the smaller appliance.

For Air Controls, see diagram 3

*In the U.K: These products must conform to BS 6539,

Fireguards for use with solid fuel appliances.

If appliance is operating unattended they must conform to

BS 3248

Advertising