Accessories, Motion detectors, Ceiling radiation dampers – Greenheck Fan CSP User Manual

Page 13: Filters, Transformers

Advertising
background image

H

1

BLK

SWITCH BOX

SWITCH

115 V MOTOR

277 V SUPPLY

277V TO 115V TRANS.

750 VA

H

2

H

3

RED

X

1

X

2

RED

BLK

BLK

Grille Motion Detectors
are available on models up
through size SP-A390 and
SP-B200.
• Rated for 115v
• UL Listed

Model MDW
For use on fan or lights.
Available shipped loose.
• Rated for 115v
• UL Listed
• Requires 2x4 handy box

Grille Mount

Wall Mount

Model T-2.0 - UL Listed
• Rated for 230/277v to 115, 2 Amps

Model T-4.3 - UL Listed
• Rated for 230/277v to 115, 4.3 Amps

Model T-6.5 - UL Listed
• Rated for 230/277v to 115, 6.5 Amps

Model T-8.6 - UL Listed
• Rated for 230/277v to 115, 8.6 Amps

Gnd.

Hot

Black

Green

Red

Load

(12.5 Amps Max.)

Neutral

Black

Red

Black

White

White

Hot

Neutral

Ground

Motion Sensor

Fan Motor and/or

Light

Green

Motion Detectors

Motion detectors may be used with Models SP and CSP fans, or fan and light combinations. Motion detectors
use a passive infrared motion detector that will automatically turn on the fan when a change in temperature is
sensed. They have a viewing area of 180 degrees, however they must be placed in the line-of-sight. They also
have an adjustable time delay shutoff setting of 1 to 20 minutes.

Ceiling Radiation Dampers

The Greenheck SP-A and SP-B ceiling
radiation dampers are UL Classified, rated
at three to four hours fire resistance, and
is available on all SP-A and SP-B fans and
fan/light combinations. This design saves
space by allowing the damper to mount
directly beneath the fan.

All dimensions shown in inches.
Add an “L” to all CRD models if fan & light combo is used.

®

Accessories

Accessories

13

Filters

Fans used in most applications, even where air is not excessively dirty, will collect airborne dirt on wheels and
motors over time. Accumulations of dirt on the fan wheel will sharply reduce performance and cause imbalance.
Dirt buildup on the motor can cause it to overheat. All of these conditions will
shorten the life of the fan. To help reduce this accumulation, washable aluminum
mesh filters are available to trap dirt before it enters the fan. These filters should
be regularly cleaned to maintain performance. The Filter Loss Chart shows the
effect the filter will have on performance. To determine the added resistance,
divide the desired cfm by the filter area (ft

2

). This will give FPM. Use this with

the filter loss chart to get the added resistance. In addition to reducing dirt
accumulations on the motor and wheel, filters also reduce sound levels.

Mesh
Filter

SP
Grille

.24

.22

.20

.18

.16

Resistance in w

.c. .14

.12

.10

.08

.06

.04

.02

.00

Velocity FPM x 100

0

1

2

3

4

5

6

7

8

9

Transformers

Transformers are available for applications requiring voltage reduction. Selection is based on motor amperage.
All transformers are shipped loose.

All dimensions shown in inches. *Aluminium or Stainless Steel Grille.

FILTER LOSS CHART

SP Model

CRD Length Width Height

A50 - A190

310

13

1

/

2

11

1

/

8

3

B50 - B200
A200 - A390

320

14

3

/

8

12

1

/

4

3

A410 - A510
A710 - A780

350

18

7

/

16

14

15

/

16

3

A - 700

700

24

3

/

16

12

1

/

4

3

A900 - A1550

360

24

3

/

16

14

15

/

16

3

SP Model

Filter Model

Filter

Designer

Grill

*Metal

Grille

Area

(ft

2

)

SP-A50 - A190

F-200

F-210

.620

SP-B50 - B200, A200 - A390

F-200

F-220

.785

SP-A410 - A510
SP-A710 - A780

NA

F-250

1.319

SP-A900 - A155

NA

F-260

1.797

Advertising
This manual is related to the following products:

SP