Deluxe ceiling fan, Standard ceiling fan – Greenheck Fan CSP User Manual

Page 17

Advertising
background image

DELUXE CEILING FAN

B

SP

STANDARD CEILING FAN

C

SP

17

HVI CFM/Static Pressure in inches of WG

Model

RPM AMPS Watts

Sones

0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 1.000

CFM

67

53

51

40

29

SP-B50

625

0.50

38

1.4

Sones

1.7

1.9

1.9

2.6

3.5

CFM

77

70

68

57

49

39

SP-B70

675

0.53

45

1.4

Sones

1.7

1.9

1.9

2.4

3.1

3.6

CFM

87 80 78 68 61 54 44 30

SP-B80

900

0.60

54

2.5

Sones

2.9 2.9 3.0 3.2 3.6 4.3 5.5 5.6

CFM

102 92 88 75 59 45 30

SP-B90

700

0.65

50

2.0

Sones

1.9 2.6 2.7 3.0 3.6 4.1 4.9

CFM

133

114

110

97

95

94

91

85

50

SP-B110 950

1.14

80

1.5

Sones

2.0 2.1 2.2 2.4 2.7 2.8 3.6 4.4 5.4

CFM 160 156 155 154 152 149 147 138 92

SP-B150 1050 1.70

129

2.5

Sones

3.0 3.3 3.3 3.7 4.3 4.5 5.0 5.3 5.8

CFM 197 195 194 191 187 184 181 166 128

SP-B200 1100 2.20

173

4.0

Sones

4.4 4.6 4.7 5.1 5.6 5.8 6.0 6.3 6.6

Performance Data

Dimensional Data

*Add 1½

inches to C dimension for incandescent light.

Mounting bracket width is 1½

inch

For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.

Model A B C

D E F Grille Wt.

50 7

1

/

2

7

1

/

2

3

5

/

8

3 1

5

/

8

1

/

2

9

1

/

4

x 9

5

Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.

Performance Data

CFM/Static Pressure in inches of WG

Model

RPM AMPS Watts

0.00

0.100

0.125

0.250

0.375

0.500

0.625

CFM

52 49 48 46 43 37 29

SP-C50

1680

0.80

46

Sones

2.9 3.6 3.6 3.9 4.2 4.8 6.3

Dimensional Data

For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.

Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.

5 UL Listed for use above tubs.
6 Available with 277 volt motor.

1 HVI sones at 0.1 wg
2 Available with light

3 Available with CRD - Ceiling Radiation Damper
4 Available with 50 Hz motors

(See CAPS for performance)

Designer Decorative

Unit

Model

A B *C

D

E

Grille

Grille

Wt.

50, 70, & 80

13

7

/

8

11

1

/

2

6

15

/

16

4

3

/

4

14

7

/

8

x 13

1

/

4

15

1

/

4

sq.

9

90, 110, 150, 200

13

7

/

8

11

1

/

2

7

15

/

16

6

1

1

/

4

14

7

/

8

x 13

1

/

4

15

1

/

4

sq.

10

1

2,3,5

2,3,5

2,3,4,5,6

3,4,5,6

2,3,4,5,6

2,3,4,5

2,3,5

A

B

C

D

E

A

B

C

D

E

F

®

®

Advertising