Problems Solving

High temperature error
(overheating)

The lamp will turn off automatically and projection will stop. Wait for about 5 minutes. After
about 5 minutes the projector will switch to standby mode, so check the following two points.
After checking, press the [Power] button to turn the power back on.

•Check that the air filter and air exhaust vent are clear, and that the projector is not positioned

against a wall.

•If the air filters are blocked, clean or replace them. s

p.57

,

p.63

If this does not solve the problem and the projector continues to overheat or the indicators continue
to show a problem when the power is turned on, stop using the projector, disconnect the power cable
from the wall outlet, and contact your dealer or the nearest address provided in the "International
Warranty Conditions" section of the Safety Instructions/World-Wide Warranty Terms booklet.

Lamp problem
Lamp timer failure
Lamp cover is open

Check that the lamp is not cracked and that the air filter and air intake vent are clear.

•Remove the lamp and check if it is cracked. s

p.59

•Clean the air filter and the air intake vent. s

p.57

•If it is not cracked

Replace the lamp and turn on the power.

If error still occurs

Replace it with a new lamp and turn on the power.

If error still occurs

Stop using the projector, disconnect the power cable from the wall
outlet, and contact your dealer or the nearest address provided in the
"International Warranty Conditions" section of the Safety
Instructions/World-Wide Warranty Terms
booklet.

•If it is cracked

Contact your dealer or the nearest address provided in the "International
Warranty Conditions" section of the Safety Instructions/World-Wide Warranty
Terms
booklet.
(You cannot continue projecting until the lamp is replaced).

Check that the lamp cover and the lamp are securely installed. s

p.59

If the lamp cover or the lamp is not securely installed, the lamp does not switch on.

When using above an altitude of about 1500m, make sure you set the "High Altitude
Mode" to "On". s