Alarm relay output – GE TRIPLEX 0150-0193C User Manual

Page 11

Advertising
background image

0150-0193C

11

Calibur DVMR

e

Triplex

See section 3.11 for information about configuring the contacts as Normally Open or Normally Closed
in the menu system.

Normally Open, Zero Potential Relay Contact: Configure in menu as Normally Open.

Normally Closed, Zero Potential Relay Contact: Configure in menu as Normally Closed

TTL Active High: Configure in menu as Normally Closed.

TTL Active Low: Configure in menu as Normally Open.

Open Collector Active On: Configure in menu as Normally Open.

High: 5V (12V Tolerant)

Low: Ground

Inputs: 1 per channel.

Open Collector Active Off: Configure in menu as Normally Closed.

pin 16

pins 18-20

Alarm Input No. 2 - 15

pins 2-15

Alarm Input No. 1

Normally Closed

(Opens During Alarm)

DVMRe Triplex DB25 Connector

Typical Alarm Device

Normally Open

(Closes During Alarm)

Typical Alarm Device

pin 1

Alarm Input No. 16

Ground

Typical wiring for Alarm #1 as Normally

Open and Alarm #16 as Normally Closed.

Refer to each alarm device's manual for specific wiring details.

Normally Open and Normally Closed Connections

Alarm Relay Output

Output: Zero potential relay contacts,
programmable in menu system as
Normally Open or Normally Closed.

Voltage: 30V (Max)

Current: 500mA (Max)

The alarm relay output is activated when an alarm condition
exists. The alarm output is only active for the duration of the
alarm.

Alarm relays can be programmed in the menu system to
respond to macros, and video loss. See section 3.11 for
information about configuring the alarms in the menu system.

pin 22

pin 25

Output Relay No. 2

pin 17

pin 21

Output Relay No. 1

DVMRe Triplex DB25 Connector

Power

Source

Alarm

Device

Typical wiring for Alarm Relays. Relays may be

programmed Normally Open or Normally Closed.

Power

Source

Controlled

Device