GE TRIPLEX 0150-0193C User Manual

Page 12

Advertising
background image

0150-0193C

12

Calibur DVMR

e

Triplex

External Alarm Acknowledge Input

External Device: Normally Open
Zero potential relay contact.

Connect a switch or similar device to ground this pin in order
to acknowledge an alarm condition, and silence associated
buzzers and relays. Connect from pin 23 to either pin 18, 19,
or 20 (ground pins).

All specifications subject to change without notice. GE-Interlogix believes all specifications
to be correct at time of printing, but no liability is assumed for omissions or errors.

AUX Port

The back panel of the unit is equipped with an Aux Port
(DB-9 style connector).

Do not attempt to wire directly to the DB-9
connector on the back panel.

1

5

6

9

DB-9 Connector on Back Panel

Connect the Accessory PCB (supplied with the audio equipped models) to the AUX port to access the
Audio features. Wire the audio input and output to the Accessory PCB per the pin out specifications
shown below.

Pin 1: Not Used.

Pin 2: Audio Out.

Pin 3: Ground.

Pin 4: Audio In.

Pin 5: Ground.

Pin 6: Not Used.

Pin 7: Ground.

Pin 8: Not Used.

Pin 9: Ground.

GND: Ground.

1
2

3
4

5

6
7

8
9

GND

Accessory PCB

RS485 Connector

Wire Type: #24 AWG, twisted pair with shield

(2-wire)

Connector Type: RJ-45

Max. Cable Length: 3200 feet / 1000 meters

Shields are grounded at one end, preferably at the
DVMR

e

Triplex.

See section 3.16 for information about configuring
the RS485 network address settings in the menu
system.

RJ-45 Pin Configuration For RS485 Port

Pin

Use

Pin

Use

1

Ground (Shield)

5

Not Connected

2

Not Connected

6

Network -VE

3

Network +VE

7

Ground (Shield)

4

Not Connected

8

Not Connected

8

2 3 4 5 6 7

1

RJ-45 socket on

back panel.

NOTE