Installation, Technical data – Gaggenau CK 481-6 User Manual

Page 28

Advertising
background image

27

Technical Data

Total connected load: 8680 W

Important notes on installation

Pay attention to the "Important notes" on page
3 and 4.

The appliance must only be connected by an
authorised specialist, paying attention to the
relevant regulations of the power supply companies
and the regional construction regulations.

The installation technician is responsible for the
correct functioning of the appliance at the place of
installation. He must instruct the user on how to
disconnect the appliance from electricity in an
emergency.

If the range is not installed over a built-in cooker,
protection against hazardous contact from below
must be ensured after assembly, e.g. by installing
an intermediate shelf that can only be detached
using a tool. The distance between the
intermediate shelf and the worktop in which the
range is recessed must be at least 60 mm (2

3

/

8

´ ´ ).

There must be a gap of at least 20 mm (

3

4

´ ´ ) at each

side between the appliance and any flammable
walls or furnishings.

If all poles of the appliances cannot be isolated
from the mains by removing an accessible plug, an
isolating device with a contact gap of at least 3 mm
must be installed (e.g. domestic fuse).

No warranty claims can be lodged for any
damage resulting from failure to observe these
instructions.

Subject to technical change without notice.

Electrical connection
The appliance must only be connected by an
authorised specialist.
All corresponding regulations must be observed.

Pay attention to the data on the rating plate. The
appliance must be properly grounded. Connect the
connecting cable to the mains.

When connecting electrical appliances in the
proximity of cooking surfaces, make sure that
connecting cables do not come into contact with hot
cooking surfaces.

This appliance may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures.
The built-in furniture and worktop where the
appliance is installed must be heat resistant up to
temperatures of 200° F/90° C.

10. Installation