Page 11

Additional Errors

Problem

Possible Cause

Measure

Code No.

No

No

W

No

Operation lamp is continuously “ON”

S20

Cooking platform does not
heat enough

U10

Non induction type pan

M10

Compare on another
cooking platform and with
an induction type pan

E

U200

1 phase is missing

M200

Check mains cable
connection

L

U12

Power board defective

M12

Replace power circuit
board

L

U14

CPU-circuit board
defective

M14

Replace CPU-circuit board

L

S21

Cooking platform
continuously on
maximum power

U50

Operational control
defective

M50

Check operational control

L

U14

CPU-circuit board
defective

M14

Replace CPU-circuit board

L

U12

Power circuit board
defective

M12

Replace power circuit
board

L

S22

Empty cooking platform
switches “on“

U220

Pan detection defective

M220 Check pan detection

L

S23

Little metallic objects are
heated on the cooking
platform

U220

Pan detection defective

M220 Check pan detection

L

No.

Operation lamp fl ashes

S24

Cooking platform does not
heat at all

U240

Pan too small (Diameter
less than 12cm, 4.75”)

M240 Use appropriate pan

E

U200

1 phase is missing

M200

Check connection of
mains cable

L

U220

Pan detection defective

M220 Check pan detection

L

U241

Short circuit on generator

M241

Replace or repair
generator

L

Legend: W = Who should complete “Measure” E = End user L = Supplier