Measure

Activity

Comment

M41

•

Measure the resistance of coil temperature sensor resistor
at 25º Celsius (77º F) resistor will read 1kOhm
at 180º Celsius (356ºF) resistor will read 3,5kOhm

•

Resistor is higher on a higher temperature (PTC-resistor)

•

Replace sensor with a value less than 900Ohm

•

For a test: Short-out the sensor with a 1kOhm fi xed RESISTER

Disconnect sensing element

M50

•

Measure operational control or main power control switch with
potentiometer: Potentiometer is 10kOhm and linear

•

On level “0”: resistor = 0 Ohm

•

On maximum level resistance= 10kOhm

•

Resistor is proportional (linear) to swing angle

Disconnect operational control
(Poti)

M60

•

Measure temperature inside the case

•

Admissible ambient temperature: 0°C/32ºF to appr. 70°C/158ºF

•

Check point is on the CPU-circuit board

M100

•

Check connection cable for serial operational control and
CPU-circuit board

M101

•

Change serial operational control

M200

•

Check mains cable, perhaps one phase missing

•

Check the building fuses

M220

•

Disconnect ST2 on CPU-circuit board and measure resistance
between brown and blue,
Measured value: 200Ohm < R < 2kOhm

• Replace

rectifi er circuit board

M240

•

Use suitable pan material

•

Test with a pan with a diameter of 24cm (4.75”)

M241

•

Disconnect mains power supply

•

Visually inspect : blackened cables, components or strip
conductors?

•

Transistor module: measure internal diodes (UF = 0.4V)

• Rectifi er: measure internal diodes (UF = 0.5V)

•

Control trafo: measure electric voltage

•

Check power supply CPU-print +24V
CPU-circuit board ST1/1 and ST1/4 (24V +/- 1V)

M251

•

Check power switch on operational control

Advertising