Problem

Possible Cause

Measure

Code No.

No

No

W

No.

Operation lamp and error lamp “OFF”

S25

Unit does not heat, no
reaction, contactor does
not work

U250

Building’s power fuses
defective, error on
electrical transmission

M201 Check mains supply

L

U251

Error on operational
control

M251 Check operational control

L

S26

Building fuses blow when
unit is switched on

U241

Short circuit in generator

M241

Repair or replace
generator

L

S27

Some cooking platforms
do not heat

U271

Generator defective

M241

Repair or replace
generator

L

S28

Unit does not heat, no
reaction, no contactor

U13

Error on DIP-Switch-
adjustment on CPU

M13

Check DIP-Switch
adjustment

L

Legend: W = Who should complete “Measure” E = End user L = Supplier

Repair Of Problems

Measure

Activity

Comment

M10

Compare on another cooking platform and with an induction
type pan

Check if the pan is appropriate to
induction cooking or not: use a
magnet.

M11

Check connection of coil

Check coil on line break

Coil overheated (brown color change)

M12

Change power circuit board

M13

Check DIP-Switch adjustment on CPU-circuit board

M14

Replace CPU-circuit board

M30

Clear ventilation system

M31

• Clean

fan

M32

Connect fan directly at 230V

M33

• Change

rectifi er circuit board

M34

Measure heat-sink temperature sensor resistor
At 25º Celsius (77ºF) resistor will read 20kOhm
At 70º Celsius (158ºF) resistor will read 3,5kOhm

Check short circuit to case

For a test: short-out the sensor with a 20kOhm fi xed resistor

Disconnect temperature sensor

M40

• Switch

off unit, cool down and switch on again. Use a pan with

cold water

Switch off fi eld!