SECTION 3 – INITIAL OPERATION

Function control

To check the function controls, the induction generator must
be totally connected.

Display

1. The external lamps must be checked.

2. The operation lamp fl ashes if a coil is not used (Searching

function).

3. This procedure must be repeated for every coil.

Pan Detection

To check the pan detection, two pans are needed: one with a
diameter of 8cm (3”) and the other with a diameter of 12cm
(4.75”) .Only the pan with a diameter of 12cm (4.75”) should
be detected. A coil should not start operation when it is not
being used.

This procedure must be repeated for every coil.

Power

Place an “induction ready” pan with a diameter of 22-24cm
(8.5”-9.5”) onto the coil. Measure the generator power
at maximum level. This should be at the nominal power
(tolerance +/- 10%). This procedure must be repeated for
every coil.

Fan

Place various pans on the coils and start the generator on
the highest level. After a few minutes the fan should start.
The fan is controlled by the temperature and starts when the
heat sink temperature is about 50ºC/122ºF.