Installation instructions, 36 ″ sealed gas cooktop, Parts included – GE JGP637 User Manual

Page 14: Materials you may need, If you have questions, call 1.800.ge.cares, Tools you will need

Advertising
background image

36

Sealed Gas Cooktop

Installation Instructions

CAUTION: Before you begin—read these
instructions completely and carefully.
• IMPORTANT—Save these instructions for

local inspector’s use.

• IMPORTANT—OBSERVE ALL GOVERNING

CODES AND ORDINANCES.

• Note to Installer—Be sure to leave these

instructions with the Consumer.

• Note to Consumer—Keep these instructions

and conversion kit for future use.

• Note—This appliance must be properly

grounded.

• IMPORTANT: Leak testing of the appliance

shall be conducted according to the
manufacturer’s instructions.

• Skill level—Installation of this appliance

requires basic mechanical skills.

Proper installation is the responsibility of

the installer.

Product failure due to improper installation

is not covered under the Warranty.

PARTS INCLUDED

Joint Sealant

14

Pipe Fittings

MATERIALS YOU MAY NEED

Shut Off
Valves

In the Commonwealth of Massachusetts:
This product must be installed by a

licensed plumber or gas fitter.

When using ball-type gas shut-off valves,

they shall be the T-handle type.

A flexible gas connector, when used,

must not exceed 3 feet.

2 Screws

Regulator

2 Hold Down
Brackets

Foam Tape

If you have questions, call 1.800.GE.CARES

or

visit our Website at:

www.GEAppliances.com

CONVERSION KIT

5 LP/
Propane
Orifices

Conversion
Label

Conversion LabelConversion LabelConversion LabelConversion LabelConversion LabelConversion Label
LP to Natural Gas ConversionLP to Natural Gas ConversionLP to Natural Gas ConversionLP to Natural Gas Conversion
For All GE Gas CooktopsFor All GE Gas CooktopsFor All GE Gas CooktopsFor All GE Gas CooktopsFor All GE Gas Cooktops
For All GE Gas CooktopsFor All GE Gas CooktopsFor All GE Gas CooktopsFor All GE Gas CooktopsFor All GE Gas
LP to Natural Gas ConversionLP to Natural Gas ConversionLP to Natural Gas ConversionLP to Natural Gas Conversion

C1

C3

20

----------------------------------

This cooktop is designed to operate on natural
gas at 4 of water column pressure. It is
shipped from the factory set for natural gas.
The convertible pressure regulator supplied
with the unit must be connected in series with
the manifold of the cooktop and must remain
in series with the supply line regardless of
whether natural or L.P . gas is being used.
FOR PROPER OPERATION, THE MAXIMUM
INLET PRESSURE TO THE REGULATOR
MUST BE NO MORE THAN 14 OF WATER
COLUMN PRESSURE. For checking the
regulator , the inlet pressure must be at least
1 (or 3.4 KP A) greater than the regulator
output setting. If the regulator is set for 4 of
water column pressure, the inlet pressure
must be at least 5 . If the regulator is set for
10 , the inlet pressure must be at least 1

1

.

The gas supply line to the cooktop should be
1/2 or 3/4 pipe.

---------------------------------------
------------

-----------------------------------

WARNING: Never reuse old flexible
connectors. The use of old flexible
connectors can cause gas leaks and
personal injury

. Always use new

flexible connectors when installing
a gas appliance.

Screw a section of pipe
onto each end of the
pressure regulator

.

C4 -------------------------------------

--------------------------------------

Pressure
Regulator

Shut Off

Valve

Electrical

Outlet

12" Below

Countertop

Screw the
regulator and
pipe connection
into the burner
box bottom.
Make sure the
top of the
regulator is
facing toward
the cabinet front,
easily accessible
through the
cabinet doors.

---------------------------------------------------------
----------------------------------------------------------

To reduce the likelihood of gas leaks, apply
teflon tape or a thread compound approved
for use with LP or natural gases to all
threaded connections.

Pressure
Regulator

-------------------------------------------

C

C2 -------------------------------------

----------------------------------------
--------------------------------

Shut Off

Valve

Electrical

Outlet

12" Below
Countertop

Install a manual shutof

Install a manual shutof f valve in the gas line

f valve in the gas line

in an easily accessible location outside the

in an easily accessible location outside the
cooktop. Be sure you know how and where to

cooktop. Be sure you know how and where to
shut of

shut of f the gas supply to the cooktop. Install

f the gas supply to the cooktop. Install

the electrical outlet 12

the electrical outlet 12 below the countertop.

below the countertop.

-------------------------

-------------------------
---------------------------

---------------------------
-------------------------

-------------------------
------------------

------------------

Conversion

Instructions

1/8

″ Drill Bit &

Electric or
Hand Drill

Phillips Head Screwdriver

Pencil

Ruler or
Straightedge

Saber Saw

TOOLS YOU WILL NEED

Pipe Wrench

Flat-Blade Screwdriver

Advertising