2 drive dc current (dc link circuit), X 1.35) – GE CS300 User Manual

Page 15

Advertising
background image

CS300

——————— Half controlled power supply for inverter DC-Link ————————

15

2.6.2 Drive DC Current (DC Link Circuit)

Rated motor

Motor

Current

Current

Fuses

power

efficiency

Dclink I

DCL

DClink I

DCL

DClink

P

Mot

h

Mot

Continuous class 1 Overload class 2

Superfast

class 1

class 2

[kW]

[A]

[A]

[A]

0,55

0,71

1,56

2,12

6

4003

4003

0,75

0,74

2,04

2,77

6

4003

4003

1,1

0,75

2,95

4,01

6

4003

4003

1,5

0,75

4,02

5,47

8

4003

4003

2,2

0,79

5,60

7,61

10

4003

4003

3

0,81

7,44

10,12

16

4003

4003

4

0,83

9,68

13,17

16

4005

4005

5,5

0,84

13,16

17,90

20

4005

4007

7,5

0,86

17,53

23,83

30

4007

4011

11

0,88

25,12

34,16

40

4011

4015

15

0,89

33,87

46,06

63

4015

4022

18,5

0,905

41,08

55,87

63

4022

4022

22

0,912

48,48

65,93

80

4022

4030

30

0,918

65,67

89,32

100

4030

4037

37

0,923

80,56

109,56

125

4037

4045

45

0,93

97,24

132,25

160

4045

4055

55

0,935

118,21

160,77

200

4055

4075

75

0,943

159,83

217,37

250

4075

4090

90

0,946

191,19

260,02

315

4090

4110

110

0,947

233,43

317,46

350

4110

4132

132

0,951

278,94

379,35

450

4132

4160

160

0,955

336,69

457,90

500

4160

4250

200

0,958

419,54

570,58

630

4250

4250

250

0,96

523,33

711,74

800

4250

4315

315

0,963

657,35

893,99

1000

4315

355

0,963

740,82

1007,52

400

0,965

833,00

1132,88

cs070

AV300 -…

The following table states the direct current values of the dc-link according to the rated power of the motor
connected to the inverter The current is calculated on the basis of the following:

-

4-pole “standard” motor

-

“typical” efficiency for “standard” motors (

η

Mot

)

-

the “typical” inverter efficiency is considered equal to 0.97 (

η

I

)

-

mains power supply voltage 3 x 380V (conservative value if referred to a rated voltage of 3 x 400V)

-

there are two value columns referring to a continuous functioning (class 1) or to a functioning during an
overload phase (class 2) (150% for 60 seconds).

The current value in column 1 is calculated as

I

DCL

= P

Mot

/ (h

Mot

x h

I

x U

LN

x 1.35)

where for column „Current Dclink I

DCL

Overload class 2“ it is obtained multiplying by 1.36.

Advertising