Servicing instructions, Servicing – Stovax Logic Hotbox & Convector Fire User Manual

Page 18

Advertising
background image

SERVICING INSTRUCTIONS

SERVICING

18

This appliance must be serviced at least once a year by a
competent person.

All tests must be serviced by best practice as described by
the current CORGI recommendations.

1.1 Before any tests are undertaken on the appliance, conduct a

gas soundness test for the property to ensure that there are
no gas leaks prior to starting work.

1.2 Before any tests are undertaken on the appliance it is also

recommended to fully check the operation of the appliance.

1.3 Special checks

1.3.1 Clean any lint or fluff from the pilot - pay particular

attention to the aeration hole in the side of the pilot.

1.3.2 Clean away any fluff or lint from under the burner

1.3.3 Check that the spark gap on the pilot is correct.

1.4 Correct any faults found during the initial tests and then

recommission the appliance conducting the usual safety
checks.

1.5 Advise the customer of any remedial action taken.

1.6 As part of the annual service, the space behind the firebox

must be inspected for any debris, which may have fallen
down the chimney.

1.7 Remove the gas fire from the firebox as detailed below.

1.8 Inspect the space behind the firebox for debris and the

condition of the chimney, the flue flow test should be carried
out now. Remove any debris and carry out any necessary
remedial work.

1. SERVICING REQUIREMENTS

Advertising