SERVICING INSTRUCTIONS

FAULT FINDING CHARTS

19

IGNITION FUNCTIONAL CHECK 1

PIL

O

T

WILL NO

T LIGHT

Ensure there is no debris around the pilot assembly

, e.g

. coal, soot, etc

which could short the spark, clean the area. Check for fluff in the pilot

aeration hole. See diagram 7.

There is a blokage in the system, check the inlet test point, the mag

seating

, valve and pilot filter

Operate the valve.

Is there a spark?

Does the pilot light?

Is the control being

operated correctly?

W

ill the pilot light

with a match?

Is the gas turned on to

the appliance?

Is the gas pressure

correct?

Has the system got

any air in it?

SYSTEM O

.K

Consult users book

and retry

Check isolation tap

and gas meter

, retry

.

Correct and retry

.

P

urge the gas pipes

and retry

See “No Spark

Chart *

Ensure gap between the

electrode and thermocouple

is as Dia. 8 and retry

.

If gap is O

.K then first

change the ignition lead and

retry

.

YES

YES

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

NO

NO

IGNITION FUNCTIONAL CHECK 2

NO SP

ARK

Ensure there is no debris around the pilot assembly

, e.g

. coal, soot, etc

which could short the spark, clean the area.

Consult users

instructions, retry

Is the valve being

operated correctly?

Reset the pilot

burner

Correct and retry

Check for defective or

damaged control knob

spindle or cam operation.

Check for the correct

location of piezo

components. Correct and

retry

.

Remove the electrode lead

from the piezo. Operate

the valve. Does a spark

jump from the piezo to

the valve body?

Operate the valve to

light the pilot, does the

valve ‘click

’?

Has ignition lead become

detached or is connection

poor?

Remove the electrode lead

from electrode with

insulated pliers hold the tip

3.5mm from the pilot

pipework,is there a spark

when the valve ‘clicks’?

Is the electrode wire

detached from the piezo

valve?

Replace the ODA unit

Replace the electrode

lead and retry

Replace the

control valve

Is the gap between electrode

and thermocouple

as in Dia 7?

NO

NO

NO

YES

YES

YES

NO

YES

YES

YES

*