User instructions – Stovax Logic Hotbox & Convector Fire User Manual

Page 7

Advertising
background image

7

PEBBLE LAYOUT - CURVED AND FLAT FRONTS

7.12 ALL THE PEBBLES HAVE AN IDENTIFICATION ON THE

UNDERSIDE. ENSURE THE PEBBLES ARE PLACED ONLY
IN THEIR CORRECT POSITIONS
.

7.13 Place the first row of pebbles on top of the front coal resting

against the frame front. All the identifications are placed

face down so they cannot be seen. See diagram 13.

7.14 Working from the outside of the appliance, place the second

row of pebbles against the rear of the first row. Note the
orientation of each pebble, as this is important to the
performance of the fire. See diagram 14.

7.15 Place the rear row of pebbles on top of the flame baffle,

these must touch the rear panel. See diagram 15.

7.16 Place the remaining five pebbles between the second and

rear rows. See diagram 16.

13

14

15

8.1 The appliance is fitted with an oxygen sensitive pilot system

will act to cut off the gas supply to the fire should the

oxygen in the room fall below its normal level. If the fire is
turned off by this device, it usually indicates that there is a
problem with the flue system, and this should be inspected
by a qualified engineer. Do not attempt to use the fire
until an engineer says it is safe to do so.

This device is not a substitute for an independently

mounted carbon monoxide detector.

9.1 This is a safety feature incorporated in all GAZCO fires

which automatically switches off the gas supply if the pilot

light goes out and fails to heat the thermocouple.

10.1 The surface coating on the coals used in your GAZCO fire

will ‘burn off’ during the first few hours of use, producing a
harmless and temporary odour. This will disappear after a
short period of use. If the odour persists, ask your installer
for advice.

11.1 This fire must be serviced every 12 months by a qualified

Gas Engineer. In all correspondence, always quote the
appliance type and serial number, which may be found on
the databadge located on a chain beneath the control valve.

12.1 Any purpose provided ventilation should be checked

periodically to ensure that it is free from obstruction.

13.1 To assist in any future correspondence, your installer should

have completed this commissioning sheet, this records, the
essential installation details of the appliance. In all
correspondence always quote the Model Number and
Serial Number.

16

8. OXYGEN DEPLETION SENSOR

9. FLAME FAILURE DEVICE

11. SERVICING

10. ‘RUNNING IN’

12. VENTILATION

13. INSTALLATION DETAILS