Installation instructions, Technical specification, Covering the following models – Stovax Logic Hotbox & Convector Fire User Manual

Page 8

Advertising
background image

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

Covering the following models

Hotbox

Convector

8306PBUC

8308PBUC

P80306PBUC

P8308PBUC

8306MCUC

8308MCUC

P8306MCUC

P8308MCUC

GAS CATEGORY

1

2h

1

3+

Natural

Butane

Propane

Gas Type

G20

G30

G31

Working Pressure

20 mb

29 mb

37 mb

Gross Input kW

High

6.7

6.7

6.7

Low

3.0

3.0

3.0

Gas Rate m

3

/hr

High

0.64

0.192

0.252

Low

0.29

0.086

0.113

Nox Class

1

1

Injector size

400

180

6x5 Rear

Aeration Size

6x15

23x15 Front

Min flue size

5” diameter

Min Flue size - Pre cast

90mm x 183 mm (16,500mm

2

min)

Min flue specifacation

T160 / N2 / 0 /D / 1

Gas Inlet

8mm

Weight (Gross)

19Kg

APPLICABLE FRONTS

FRONT

HOTBOX

CONVECTOR

DESIGNIO

8251MA

8251MA

EVOLUTION

8255MB, 8255BS

8257MB, 8257BS

HOLYROOD

8391
8397
8150

8391
8397
8150

INFINITI

8249BS

8249BS

PROGRESS

8253BS

8253BS

RICHMOND

N/A

8678

SPANISH

8382, 8385
8388, 8153

8382, 8385
8388, 8153

VICTORIAN

CONVECTOR

N/A

4262, 4263

ART NOUVEAU

CONVECTOR

N/A

4264, 4265

COMBINATION

CONVECTOR

N/A

4362, 4363

8